• SUMMARY OF THE FAULTS





D01

d01: water intake fault (tap).

d07: overflow/leak protection fault

D07

D02

d02: draining fault.

d08: sprinkler distribution fault.

D08

D03

d03: heating fault.

d11: sprinkler distribution fault.

D11

D04

d04: temperature sensor fault.

d12: water level fault (siphoning
through drain tube)

D12

D05

d05: low pump flow fault.

d13: overheating fault.

D13

D06

d06: high pump flow fault.

d14: bad drain tube connection or

tap flow insufficient or filters dirty.

D14

• BEFORE CALLING FOR SERVICE

Problem

Possible

C

auses

What to do?

The door falls heavily when
opened (integratable model)

- Door springs not tensioned

enough to compensate for the
weight of the panel.

- Tighten the two tensioning

screws accessible in the bot-
tom section above the front
feet.

The door does not stay horizontal
when open or returns too quickly
(integratable model)

- Door springs tensioned too

much.

- No wooden panel.

- Loosen the two tensioning

screws accessible in the bot-
tom section above the front
feet.

- Fit a temporary wooden panel

on the appliance and adjust
the springs.

The door catches when closing - Appliance not stable

- Door not centred on the tub

- Adjust the feet.
- Re-centre by adjusting the

rear feet.

The upper basket does not stay
in the high position

- Poor manipulation (the basket

is being pulled upwards too
quickly)

- Act more progressively (see

instructions), one side and
then the other.

Small leak around or under the
appliance (move the appliance
to locate the leak)

- Leak from the tap.

- Leak from the appliance.
(Cf. table fault d07).

- Check that a seal is fitted and

retighten the nut.

- Close the water tap and call a

technician.

Small leak at the door

- Appliance not stable or not level
- Door not centred on the tub.

- Adjust the feet.
- Re-centre by adjusting the rear

feet.

Tip:

If one of the above faults occurs and you need to call a repair man, remember to tell him

the message displayed (d01, d02..) as this information will help him.