1. ON/OFF BUTTON: Used to turn the unit ON and OFF.
2. AUGER PULSE LIGHT: This light will flash in conjunction with

the auger.

3. HEAT OUTPUT INDICATOR: Shows the present heat output

setting.

4. HEAT LEVEL ADJUSTMENT: When pressed, will change the heat

setting of the unit from low to high. the fan runs up and down with

the heat seting.

Notes:

• The convection blower speed will vary automatically with the feed

rate.

• Due to varying fuel qualities this pellet stove may not operate on

lower Heat Level settings. If your unit goes out when on a low

setting move the heat level up to a higher setting.

• The lowest and highest heat levels on this pellet stove are used

for adjusting and accommodating for different pellet sizes and the

varying energy produced by the fuels. The size of the pellets will

change the volume of fuel being fed.

• The unit should be run at a setting where the least amount of

cleaning of the burn pot is needed.

The combustion exhaust blower is a variable speed blower controlled by the heat output setting. This

blower will increse or decrease the blower speed as the heat output setting is turned up or down.
SPECIAL NOTES:
Pellet quality is a major factor in how the pellet stove will operate. If the pellets have a high moisture

content or ash content the fire will be less efficient and has a higher possibility of the fire building up and

creating clinkers (hard ash build-up). If this happens, move the Slider / Damper to the right slightly to

increase the air flow to the fire.

S

TOVE

C

ONTROLS

:

Figure 3: Control panel.