Electrical connections

Take utmost care when handling your appliance so as not
to cause any damages to the cooling unit with consequent
possible fluid leakages.

During normal operation, the condenser and compres-
sor at the back of the appliance heat up considerably.
Always ensure that there is adequate ventilation as a
failure to do this will result in component failure and
possible food loss. See installation instructions.

Important: if the supply cord is damaged, it must be
replaced by a special cord or assembly available from
the manufacturer or its service agent.

Positioning

Unpack the cabinet and check that it is in good condi-
tion and free of any transport damage.

Place the refrigerator away from direct sunlight and
heat sources.

Avoid prolonged exposure of the appliance to direct
sunlight.

For safety reasons, minimum ventilation must be as
shown in Fig.

23

Attention: keep ventilation openings clear of obstruction.

• It is necessary that the niche is provided with a conduct

of venti-lation having the following dimensions:

Depth 50 mm

Width 540 mm

The climate classification can be found on the rating plate,
which is located inside the cabinet on the left hand wall.

The following table shows which ambient temperature is
correct for each climate classification:

Electrical connection

Before plugging in, ensure that the voltage and frequency
shown on the serial number plate correspond to your do-
mestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized auto-
transformer must be used.

Important
The appliance must be earthed.

The power supply cable plug is provided with a contact for
this purpose.
If the domestic power supply socket is not earthed. connect
the appliance to a separate earth in compliance with cur-
rent regulations, consulting a specialist technician.
The Manufacturer declines all responsibility if the
above safety precautions are not observed.

This appliance complies with the following E.E.C.
Directives:

- 87/308 EEC of 2/6/87 relative to radio interference sup-
pression.
- 73/23 EEC of 19.2.73 (Low Voltage Directive) and subse-
quent modifications.
- 89/336 EEC of 3.5.89 (Electromagnetic Compatibility Di-
rective) and subsequent modifications.

Attention!
It must be possible to disconnect the appliance

from the mains power supply; the plug must therefore be
easily accessible after installation.

Climate

classification

for an ambient tempera-

ture of

SN

+10 to +32°C

N

+16 to +32°C

ST

+18 to +38°C

T

+18 to +43°C