3) Auto Music Sensing:

Amplifier automatically

turns on when it senses

signal.

4) Bypass/Lowpass:

Set to Bypass to use as a

2 channel or 2.1 channel

amplifier. Set to Lowpass

to use as a 1 channel or

subwoofer amplifier.

5) Phase Setting:

Use to correct subwoofer

frequency arrival times.

Can only use when in “Low

Pass” setting.

6) Crossover Setting:

Room equalization for

subwoofer frequencies.

Can only use when in “Low

Pass” setting.

7) Volume Setting:

Set based on the input

level and power rating of

your load.

B) Turn the phase knob to zero and place the meter in the listening

position.

C) While the system is playing the 50Hz tone, read the meter.

D) Rotate the phase knob until the meter reads the highest

possible.

E) Take note of the position for future reference.

6) Crossover Setting:

As a rule of thumb:

A) If you are powering the THOR In-Wall SUB10, the Q10B tactile

transducer, or a large subwoofer (12” - 18”), set the crossover to

50Hz - 100Hz.

B) If you are powering a MQB-1 tactile transducer, a 10” subwoofer,

or small front speakers, set the crossover to 70Hz, or the 9

o’clock position.

C) If you powering a small subwoofer (8”) or small speakers, set the

crossover to 100Hz, or the 12 - 2 o’clock position.