SPECIFICATIONS

Measuring Range:

15A - 3000A

Output Sensitivity:

1mV/3A

Accuracy: (at 250C)

±1% of range

Frequency Range:

10Hz to 5kHz

Phase Error:

±1º (45 to 65 Hz) ±10º (at 5kHz)

Linearity:

±0.2% of reading from 10% to 100% of range

Position Sensitivity:

±2% of range, cable >25mm (1”) from coupling

External Field:

±1% with cable >200m (8”) from head

Minimum Load:

100kΩ for specified accuracy

Noise Level

1.0mV rms (0.3% of range)

Operating Temperature:

-20

o

C to 85

o

C (-4

o

F to 185

o

F) Electronics

Storage Temperature:

-20

o

C to 85

o

C (-4

o

F to 185

o

F) Electronics

Gain Variation

±0.08%/

o

C

Common Mode Voltage:

Voltage between the Output and Earth must not exceed
30V.

Power Supply:

2 x AA/MN1500/LR6 (1.5V) batteries.

Battery Life:

4000 hours, 3000 hours typical (4 months cont.)

Low Battery Indication:

Red LED flashing

External Power:

Battery eliminator, via 2.1mm connector, 3V DC Socket
type A16M500

Safety:

Voltage between the Output and Earth must not exceed
30V.

EMC:

EN61326: 1998

Enclosure:

IP5X, Flame retardant UL94-VO rated

Material:

Valox 357 X

Output Connections:

Hypotronics connector type DO1EEB306FST

Weight:

0.19kg (0.4lb)

Measuring Head
Cable length:

610mm (24 inches), double insulated

Cable Diameter:

14.3mm (0.562 inches)

Bend Radius:

38.1mm (1.5 inches) minimum

Connecting Cable:

2m (78.7 inches) long, double insulated

Material:

TPE rubber Polypropylene, UL94-VO rated

Operating Temperature:

-20

o

C to +90

o

C (-4

o

F to 194

o

F) Head

Storage Temperature:

-40

o

C to _105

o

C (-40

o

F to 221

o

F) Head

Safety:

BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2

Weight:

0.18kg (0.4 lb)

10

SPECIFICATIONS

Measuring Range:

15A - 3000A

Output Sensitivity:

1mV/3A

Accuracy: (at 250C)

±1% of range

Frequency Range:

10Hz to 5kHz

Phase Error:

±1º (45 to 65 Hz) ±10º (at 5kHz)

Linearity:

±0.2% of reading from 10% to 100% of range

Position Sensitivity:

±2% of range, cable >25mm (1”) from coupling

External Field:

±1% with cable >200m (8”) from head

Minimum Load:

100kΩ for specified accuracy

Noise Level

1.0mV rms (0.3% of range)

Operating Temperature:

-20

o

C to 85

o

C (-4

o

F to 185

o

F) Electronics

Storage Temperature:

-20

o

C to 85

o

C (-4

o

F to 185

o

F) Electronics

Gain Variation

±0.08%/

o

C

Common Mode Voltage:

Voltage between the Output and Earth must not exceed
30V.

Power Supply:

2 x AA/MN1500/LR6 (1.5V) batteries.

Battery Life:

4000 hours, 3000 hours typical (4 months cont.)

Low Battery Indication:

Red LED flashing

External Power:

Battery eliminator, via 2.1mm connector, 3V DC Socket
type A16M500

Safety:

Voltage between the Output and Earth must not exceed
30V.

EMC:

EN61326: 1998

Enclosure:

IP5X, Flame retardant UL94-VO rated

Material:

Valox 357 X

Output Connections:

Hypotronics connector type DO1EEB306FST

Weight:

0.19kg (0.4lb)

Measuring Head
Cable length:

610mm (24 inches), double insulated

Cable Diameter:

14.3mm (0.562 inches)

Bend Radius:

38.1mm (1.5 inches) minimum

Connecting Cable:

2m (78.7 inches) long, double insulated

Material:

TPE rubber Polypropylene, UL94-VO rated

Operating Temperature:

-20

o

C to +90

o

C (-4

o

F to 194

o

F) Head

Storage Temperature:

-40

o

C to _105

o

C (-40

o

F to 221

o

F) Head

Safety:

BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2

Weight:

0.18kg (0.4 lb)

Advertising