1) SAFETY
This manual contains information and warnings that must be followed for operating the

instrument safely and maintaining the instrument in a safe operating condition. If the
instrument is used in a manner not specified by the manufacturer, the protection

provided by the instrument may be impaired.

The meter meets the requirements for double insulation to IEC61010-2-032(1994),
EN61010-2-032(1995), UL3111-2-032(1999):


Category III 600 Volts AC and DC.


PER IEC61010 OVERVOLTAGE INSTALLATION CATEGORY

OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be

supplied from the fixed installation.
Note – Examples include household, office, and laboratory appliances.

OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.

Note – Examples include switches in the fixed installation and some equipment for
industrial use with permanent connection to the fixed installation.

OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the

installation. Note – Examples include electricity meters and primary over-current
protection equipment.


TERMS IN THIS MANUAL

WARNING identifies conditions and actions that could result in serious injury or

even death to the user.

CAUTION identifies conditions and actions that could cause damage or

malfunction in the instrument.