Electrical specifications – Amprobe 38XR-A Professional-Digital-Multimeter User Manual

Page 17

Advertising
background image

13

Safety:

Conforms to EN61010-1, Rev-2 CAT III
1000V, CAT IV 600V, class 2, pollution
degree II; CSA 22.2 -1010-1.

P $ !

54CJ

In accordance with
IEC 1010-1

EMC: Conforms to EN61326-1.

This product complies with

requirements of the following European

Community Directives: 89/ 336/ EEC

(Electromagnetic Compatibility) and 73/

23/ EEC (Low Voltage) as amended by

93/ 68/ EEC (CE Marking). However,

electrical noise or intense

electromagnetic fields in the vicinity of

the equipment may disturb the

measurement circuit. Measuring

instruments will also respond to

unwanted signals that may be present

within the measurement circuit. Users

should exercise care and take

appropriate precautions to avoid

misleading results when making

measurements in the presence of

electronic interference.

Electrical Specifications

(Accuracy at 23 °C ±5 °C, <75 % relative
humidity)

DC VOLTS
Ranges: 1000 mV, 10 V, 100 V, 1000 V

( auto/manual ranging )
Resolution: 100 µV
Accuracy: ±(0.25 % rdg + 5 dgts)
Input impedance: 10 M

O

Overload protection: 1000 V dc or 750 V

ac rms
AC VOLTS

true rms (45 Hz to 2 kHz)

Ranges: 1000 mV, 10 V, 100 V, 750 V

(auto/manual ranging)
Resolution: 100 µV
Accuracy:
±(1.2 % rdg + 10 dgts) 45 Hz to 500 Hz
±(2.0 % rdg + 10 dgts) 500 Hz to 2 kHz
±(2.0 % rdg + 10 dgts) 45 Hz to 1 kHz

on 750 V range
Peak Hold accuracy: ±(3.0 % + 200

dgts) on 100 V, 750 V range;
1000 mV, 10 V ranges unspecified

Crest Factor:

≤ 3

Input impedance: 10 M

O

AC coupled true rms specified from 5 %

to 100 % of range overload protection:

1000 V dc or 750 V ac rms
AC+DC VOLTS

(45Hz to 2kHz)

Ranges: 1000 mV, 10 V, 100 V, 750 V

(auto/manual ranging)
Resolution: 100 µV
Accuracy:
±(1.5 % rdg + 10 dgts) 45 Hz to 500 Hz

±(2.5 % rdg + 10 dgts) 500 Hz to 2k Hz
±(2.5 % rdg + 10 dgts) 45 Hz to 1 kHz

on 750 V range
Crest Factor:

≤ 3

Input impedance: 10 M

O

DC coupled true rms specified from 5 %

to 100 % of range
Overload protection: 1000 V dc or 750 V

ac rms
DC CURRENT
Ranges: 100 uA, 1000 µA, 10 mA,

100 mA, 400 mA, 10A (auto/manual

ranging)
Resolution: 0.1 µA
Accuracy:
±(0.5 % rdg + 10 dgts) on 100 uA

range
±(0.5 % rdg + 5 dgts) on 1000 µA to

400 mA ranges
±(1.5 % rdg + 10 dgts) on 10A range
Input protection:
0.5A/1000V fast blow ceramic fuse

6.3×32mm on µA/mA input
10A/1000V fast blow ceramic fuse

10×38mm on 20A input

10A input: 10 A for 4 minutes maximum
followed by a 12 minute cooling period

Burden voltage:

μ

A Range:

1 mV/ 1

μ

A

mA Range:

1 mV/ 1 mA

10A:

30 mV/ 1 A

Advertising