15

Dimension:

186mm/7.3in (L) x 87mm/3.4in (W) x
35.5mm/1.4in (H); 198mm/7.8in (L) x 97mm/3.8in
(W) x 55mm/2.2in (H) with holster

Weight:

340g/0.8lb; 430g/1.0lb with holster

Electrical Specifications

Accuracy is (% reading digits + number of digits) or otherwise specified, at
23°c 5°c & less than 75% relative humidity.

ACV & ACA accuracies are specified from 5 % to 100 % of range or otherwise
specified. maximum crest factor <3:1 at full scale & <6:1 at half scale, and with
frequency spectrums, besides fundamentals, fall within the meter specified AC
bandwidth for non-sinusoidal waveforms.

DC Voltage

RANGE

ACCURACY

50.00 MV

0.12% + 2D

500.0 MV

0.06% + 2D

5.000V, 50.00V, 500.0V, 1000V

0.08% + 2D

NMRR: >60DB @ 50/60HZ
CMRR: >120DB @ DC, 50/60HZ, RS=1K
Input Impedance: 10M, 16pF nominal (44pF nominal for 50mV & 500mV
ranges)

AC Voltage

RANGE

ACCURACY

50HZ -- 60HZ

50.00MV, 500.0MV, 5.000V,

50.00V,500.0V, 1000V

0.5% + 3D

40HZ -- 500HZ

50.00MV, 500.0MV

0.8% + 3D

5.000V, 50.00V, 500.0V

1.0% + 4D

1000V

1.2% + 4D

Advertising