Avago Technologies 3ware SAS 9750-16i4e User Manual
3ware® sata+sas raid controller card, Cli guide
Advertising
This manual is related to the following products:
3ware SAS 9750-24i4e, 3ware SAS 9750-4i, 3ware SAS 9750-4i4e, 3ware SAS 9750-8e, 3ware SAS 9750-8i, 3ware 8006-2LP, 3ware 8006-2LP (Channel), 3ware 9550SXU-4LP, 3ware 9550SXU-4LP (Channel), 3ware 9550SXU-8LP, 3ware 9550SXU-8LP (Channel), 3ware 9650SE-12ML, 3ware 9650SE-12ML (Channel), 3ware 9650SE-16ML, 3ware 9650SE-16ML (Channel), 3ware 9650SE-24M8, 3ware 9650SE-24M8 (Channel), 3ware 9650SE-2LP, 3ware 9650SE-2LP (Channel), 3ware 9650SE-4LPML, 3ware 9650SE-4LPML (Channel), 3ware 9650SE-8LPML, 3ware 9650SE-8LPML (Channel), 3ware 9690SA-4I, 3ware 9690SA-4I (Channel), 3ware 9690SA-4I4E, 3ware 9690SA-4I4E (Channel), 3ware 9690SA-8E, 3ware 9690SA-8E (Channel), 3ware 9690SA-8I, 3ware 9690SA-8I (Channel)
Table of contents
Document Outline
- Table of Contents
- About this CLI Guide
- Introduction to the 3ware Command Line Interface
- CLI Syntax Reference
- Common Tasks Mapped to CLI Commands
- Terminology
- Syntax Overview
- Shell Object Commands
- Controller Object Commands
- /cx show
- /cx show attribute [attribute ...]
- /cx show all
- /cx show alarms [reverse]
- /cx show events [reverse]
- /cx show AENs [reverse]
- /cx show diag
- /cx show phy
- /cx show rebuild
- /cx show rebuildmode
- /cx show rebuildrate
- /cx show selftest
- /cx show verify
- /cx show verifymode
- /cx show verifyrate
- /cx add type=<RaidType> disk=<p:-p> [stripe=size] [noscan] [group=<3|4|5|6|7|8|9|10|11|12|13|14|15|16>] [nowrcache] [nordcache| ...
- /cx rescan [noscan]
- /cx commit
- /cx flush
- /cx update fw=filename_with_path [force]
- /cx add rebuild=ddd:hh:duration
- /cx add verify=ddd:hh:duration
- /cx add selftest=ddd:hh
- /cx del rebuild=slot_id
- /cx del verify=slot_id
- /cx del selftest=slot_id
- /cx set dpmstat=on|off
- /cx set rebuild=enable|disable|1..5
- /cx set rebuildmode=<adaptive|lowlatency>
- /cx set rebuildrate=<1..5>
- /cx set verify=enable|disable|1..5
- /cx set verify=advanced|basic|1..5
- /cx set verify=basic [pref=ddd:hh]
- /cx set verifymode=<adaptive|lowlatency>
- /cx set verifyrate=<1..5>
- /cx set selftest=enable|disable
- /cx set spinup=nn
- /cx set stagger=nn
- /cx set autocarve=on|off
- /cx set carvesize=<1024..32768>
- /cx set autorebuild=on|off
- /cx set autodetect=on|off disk=<p:-p>|all
- Unit Object Commands
- /cx/ux show
- /cx/ux show attribute [attribute ...]
- /cx/ux show all
- /cx/ux remove [noscan] [quiet]
- /cx/ux del [noscan] [quiet]
- /cx/ux start rebuild disk=<p:-p...> [ignoreECC]
- /cx/ux start verify
- /cx/ux stop verify
- /cx/ux flush
- /cx/ux set autoverify=on|off
- /cx/ux set wrcache=on|off [quiet]
- /cx/ux set rdcache=basic|intelligent|off
- /cx/ux set identify=on|off
- /cx/ux set ignoreECC=on|off
- /cx/ux set name=string
- /cx/ux set qpolicy=on|off
- /cx/ux set rapidrecovery all|rebuild|disable [quiet]
- /cx/ux set storsave=protect|balance|perform [quiet]
- /cx/ux migrate type=RaidType [disk=p:-p] [group=3|4|5|6|7|8|9|10|11|12|13|14|15|16] [stripe=size] [noscan] [nocache] [autoverify]
- Port Object Commands
- Phy Object Commands
- BBU Object Commands
- Enclosure Object and Element Commands
- /cx/ex show
- /cx/ex show attribute [attribute ...]
- /cx/ex show all
- /cx/ex/slotx show
- /cx/ex/slotx show identify
- /cx/ex/slotx set identify=on|off
- /cx/ex/fanx show
- /cx/ex/fanx show identify
- /cx/ex/fanx set identify=on|off
- /cx/ex/fanx set speed=<0..7>
- /cx/ex/pwrsx show
- /cx/ex/pwrsx show identify
- /cx/ex/pwrsx set identify=on|off
- /cx/ex/tempx show
- /cx/ex/tempx show identify
- /cx/ex/tempx set identify=on|off
- /cx/ex/almx show
- /cx/ex/almx set alarm=mute|unmute|off
- /cx/ex update fw=filename_with_path [sep=n] [force]
- /cx/ex show firmware
- Help Commands
- Command Logging
- Return Code