Installing the eXtremeRAID 3000 Fibre Channel RAID controller is no
more difficult than installing any 32 bit or 64 bit PCI controller. The
eXtremeRAID 3000 controller, with two Fibre channels and one internal
SCSI channel, connects into any PCI slot on the motherboard. Follow these
steps and the installation procedures in this chapter.

WARNING

Working with the system covers off and power
applied to the system can result in shock and
serious injury.

This controller is furnished with a nonvolatile
RAM (NVRAM) chip that uses a sealed lithium
battery/crystal module. Replace the module only
with the same or equivalent type recommended by
the manufacturer.

Dispose of the used battery/crystal module
according to the manufacturer’s instructions.
Never incinerate a battery as it could explode and
cause serious injury.

1. Read all of the instructions in this chapter completely before proceed-

ing. Follow the Notes, Cautions, and Warnings described in this manual
and marked on the equipment.

2. Power off the system and disconnect the power cables before starting

the installation. Refer to the instructions provided in your system
documentation. Do not disconnect cables or power cords while system
power is on.

3. Follow electrostatic discharge (ESD) safe procedures. Use a grounded

wrist strap or ESD safe footwear, and work in an ESD safe area.

4. Perform a safety check of the installation before powering on the

system.

• Make sure that the cabling Pin 1 location is correct and that all

cables are firmly seated in the connectors.

• Make sure all SCSI conventions (cable type, cable length,

termination, etc.) are correct, see Table 2-2.