2 verifying correct installation, Verifying correct installation – Avago Technologies LSI20320 User Manual

Page 19

Advertising
background image

Fusion-MPT FCode Fibre Channel Commands

13

Copyright © 2000-2004 by LSI Logic Corporation. All rights reserved.

If your system does not identify the Fibre Channel disks on your
LSI Logic/IntraServer adapter, check the following:

1.

Is the Fibre Channel enclosure powered ON?

2.

Does the LED on the adapter indicate LINK? (LINK is valid only after
the device is probed.)

3.

Does the LED on the switch or remote enclosure indicate LINK?

4.

Does the LINK-SPEED parameter selected by the adapter match
that of the bus (1G, 2G or Auto)?

If you do not see disks, the following additional debug information may
help to identify the problem.

4.2

Verifying Correct Installation

Use this procedure to verify installation of your Fusion-MPT adapter in
the system.

1.

Power on the system.

2.

When the banner is displayed, press the Stop-A keys to interrupt the
boot process and stop at the ok prompt.

3.

Use the show-devs command to list the system devices. You should
see an output similar to the following:

Advertising