161 network-clock selector – PLANET MGSW-28240F User Manual

Page 261

Advertising
background image

Command Guide of MGSW-28240F

Default:

None

Usage Guide:

To configure EEC options of network-clock

Example:

To configure EEC options (eec1) of network-clock

Switch# configure terminal

Switch (config)# network-clock option eec1

4.2.161 network-clock selector

Command:

network-clock selector { { manual clk-source <clk-source : 1-2> } | selected |

nonrevertive | revertive | holdover | freerun }

network-clock network-clock

selector Selection mode of nominated clock sources

freerun Selector is forced in free run

holdover Selector is forced in holdover

manual Selector is manually set to the chosen clock source

<clk-source : 1-2> Clock source number

clk-source clk-source - commands related to a specific clock source

nonrevertive Selector is automatically selecting the best clock source - non revertively

revertive Selector is automatically selecting the best clock source - revertively

selected Selector is manually set to the pt. selected clocfk source (not possible in unlocked mode)

Default:

None

Usage Guide:

To configure Clock Selection Mode of network-clock

Example:

To configure Clock Selection Mode (Forced Free Run) of network-clock

-261-