Port Setting

Baud Rate: Select data baud rate of RS-485 interface that

pan-tilt camera cradle will accept. When the length of

RS-485 connection is very long (longer than 200M), it’s not

recommended to use high speed connection (greater than

2400bps).

Data Bits: Select data bits of RS-485 connection.

Parity: Select parity bit “odd, even, or space”.

Stop Bit: Select stop bit “1 or 2”.

Use Pelco-D

Select this option and RS-485 interface will output pan-tile control

signal in Pelco-D format. This format is widely accepted by most of

pan-tilt pan-tilt camera cradles.

You have also input pan-tilt camera cradle’s address code in

‘Address’ field. This code must be identical to pan-tilt camera

cradle’s address code.

Use Custom

Protocol

When the pan-tilt camera cradle does not support Pelco-D protocol,

you can define a protocol’s detail by this function.

Please refer to pan-tilt camera cradle’s user manual to define

the protocol.

Home/Up/Down/Left/Right: Input the command string

used to move pan-tilt camera cradle to home or

up/down/left/right position. You can click ‘Test’ button to

send command string for testing.

Command 1 ~ 5: You can define extra pan-tilt camera

cradle control strings here by giving it a name (Command

Name) and command string (Hexadecimal Message). You

can also click ‘Test’ button to send command string for

testing.

When you finish with above settings, click ‘Apply’ button to save changes.

 

 

 

 

 

 