PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 10.

b. If the walking belt is overtightened, treadmill perfor-

mance may decrease and the walking belt may be
permanently damaged. Remove the key and

UN-

PLUG THE POWER CORD. Using the included allen
wrench, turn both rear roller bolts counterclockwise
1/4 of a turn. When the walking belt is properly tight-
ened, you should be able to lift each edge of the
walking belt 3 to 4 inches off the walking platform. Be
careful to keep the walking belt centered. Then, plug
in the power cord, insert the key, and run the treadmill
for a few minutes. Repeat until the walking belt is
properly tightened.

c. If the walking belt still slows when walked on, please see the front cover of this manual.

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key

and

UNPLUG THE POWER CORD. If the walking

belt has shifted to the left, use the allen wrench to
turn the left rear roller bolt clockwise 1/2 of a turn;

if

the walking belt has shifted to the right, turn the
bolt counterclockwise 1/2 of a turn. Be careful not to
overtighten the walking belt. Then, plug in the power
cord, insert the key, and run the treadmill for a few
minutes. Repeat until the walking belt is centered.

b. If the walking belt slips when walked on, first remove

the key and

UNPLUG THE POWER CORD. Using

the allen wrench, turn both rear roller bolts clockwise
1/4 of a turn. When the walking belt is correctly tight-
ened, you should be able to lift each edge of the
walking belt 3 to 4 inches off the walking platform. Be
careful to keep the walking belt centered. Then, plug
in the power cord, insert the key, and walk on the
treadmill for a few minutes. Repeat until the walking
belt is properly tightened.

PROBLEM: The chest pulse sensor does not function properly

SOLUTION: a. If the chest pulse sensor does not function properly, see CHEST PULSE SENSOR TROUBLE-

SHOOTING on page 9.

b. If the chest pulse sensor still does not function properly, the battery

should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.

Next, remove the old battery from the sensor unit. Insert a new

CR

2032 battery, making sure that the writing is on top. In addition, make
sure that the rubber gasket is in place in the sensor unit. Replace the
battery cover and turn it to the closed position.