16012-1-0504

CLEARANCES

OPTIONAL FLOOR STAND INSTALLATION

SRS-18* and SRS-30 Floor Stand Installation

1. Align clearance holes on floor stand with screw holes on

bottom of heater, as shown in Figure 5.

2. Attach floor stand to heater with (4) screws provided with

floor stand.

3. Connect the gas line.
* SRS-18 floor stand can not be used in a bedroom installation.

BF-10 must be wall mounted in a bedroom installation.

Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other
combustible material, other than wood flooring, the appliance
shall be installed on a metal or wood panel extending the full width
and depth of the appliance.

Attention: Optional SRS-18 and SRS-30 Floor Stand meets
requirement.

The base referred to in this section does not mean the fire-proof
base as used on wood stoves. The protection is for rugs that are
extremely thick and light colored tile.

Figure 5

BF-30

Figure 4

BF-10 and BF-20

Figure 3

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Do not install in alcove or closet.

BF-10/BF-20

BF-30

Left side

5" (127mm)

8" (203mm)

Right side

5" (127mm)

8" (203mm)

Rear wall

0" (0mm)

0" (0mm)

Ceiling

36" (914mm)

36" (914mm)

Minimum vertical clearance from a projection
above the appliance (shelves, window sills, etc.)

36" (914mm)

36" (914mm)

Floor (top surface of carpeting, tile, etc.)

2" (51mm)

2" (51mm)

Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.