Operating instructions – Enviro C-11256 User Manual

Page 7

Advertising
background image

7

Operating Instructions

C

ONTROL

B

OARD

F

UNCTIONS

:

1. ON/OFF BUTTON: Used to turn the unit ON and OFF manually.
2. FUEL TYPE BUTTON: Used to switch between fuel type modes; Pellet (for all qualities of wood

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

FEED TRIM

ON/OFF

FUEL TYPE

HEAT LEVEL

AUTO/OFF

HIGH/LOW

MANUAL

PELLET

C-11256

MULTIFUEL

1

2

3

4

5

6

7

pellets) and Multifuel (for all fuels including wood

pellets). When set on Multifuel it will run at a reduced

High Feed Rate with wood pellets. NOTE: Fuel Type

can only be chnaged when the unit is cold.

3. THERMOSTAT SWITCH: Sets the unit’s control

mode; AUTO/OFF or HIGH/LOW (when using a

Thermostat or Timer) or MANUAL.

4. FUEL TYPE LIGHTS: Shows the present Fuel Type

selected; Pellet is green and Multifuel is yellow. The

light flashs during start-up and stops flashing when the

49°C (120°F) switch closes.

5. HEAT OUTPUT INDICATOR: Shows the present

Heat Level output setting and the Feed Trim while it is

being adjusted.

6. HEAT LEVEL ADJUSTMENT BUTTONS: When

pressed, will change the heat setting of the unit from

low to high. Arrow up button to increase heat and

arrow down to decrease heat.

7. FEED TRIM BUTTON: Used in conjunction with the

Heat Level adjustment buttons to adjust the Feed Trim.

It can be increased by two (2) feed settings or it can be

decreased by two (2) feed settings. The Feed Trim can

only be adjusted one setting at a time. This button can

also be used to “prime the auger system”.

Figure 2: Circuit Board Control Panel Decal

A

UTOMATIC

S

AFETY

F

EATURES

OF

Y

OUR

P

ELLET

S

TOVE

:

A. EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust

temperature drops below 49°C (120°F).

B. HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93°C (200°F), the auger will

automatically stop, the stove will shut down, and it will display a #4 flash code. If this happens, call

your local dealer to reset the 93°C (200°F) high limit switch. ALSO FIND THE REASONS WHY THE

UNIT OVERHEATED.

C. VACUUM SWITCH: If the combustion fan fails or the exhaust vent becomes blocked this switch will

stop the auger feed motor and the fire will go out.

O

PERATING

Y

OUR

P

ELLET

S

TOVE

:

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH BOX OPEN. Keep hopper lid closed

except during re-fuelling.
CAUTION:
When operating during adverse weather, such as high winds or freezing rain, if the unit

exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust

outlet.