Extron Electronics VC 50 User Manual

Vc 50, Remote connector pin configuration, Audio level setting procedure

Advertising
background image

68-1154-01

Rev. B

10 08

As shown below with the MPA 122 Mini Power Amplifier, the Extron VC 50 serves to remotely

control volume levels for Extron audio amplifiers.

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

EMEA

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

PO

WE

R

OU

TPU

TS

4/8

Ohm

s

INP

UT

S

L

R

L

R

RE

MO

TE

10V
VO

L/M

UT

E

L

MP

A 1

22

R

C

US

Projector

Audio
Output

Extron
VC 50

Remote Volume
Controller

VC

50

VO

LU

ME

Extron
MPA 122

Mini Power
Amplifier

VC 50

Remote Connector Pin Configuration

As shown at right,
Pin 1 is reference voltage.
Pin 2 is volume control with DC voltage.
Pin 3 is ground.

N All nominal levels are at ±10%.

For proper volume control, use all three pins when
connecting the device (see diagram).

The Extron VC 50 is a remote volume controller designed to work with the Extron PoleVault

switcher (PVS 204SA with amp), the MLP (Mic to Line Pre-amplifier), and the MPA series

audio amplifiers (e.g. MPA 122).

Mounted into standard one-gang wall box or mud ring, the VC 50 has a rotary volume control

knob, which provides easy adjustment and ensures precise volume levels.

Captive screw connectors on the back panel provide quick and easy connectivity.

Audio Level Setting Procedure

To set the system level not to exceed the maximum volume when

using the VC 50, do the following:
1. Reduce the power amplifier volume to minimum.
2. Turn the Volume knob on the VC 50 to the maximum position.
3. Slowly turn up the power amplifier volume to the maximum