Furniture mounting, Through-desk mounting, Furniture mounting -4 through-desk mounting -5 – Extron electronic Fiber Optics Fox 4G DA8 User Manual

Page 9: Installation and operation, cont’d

Advertising
background image

FOX 4G DA8 • Installation and Operation

Installation and Operation, cont’d

2-4

FOX 4G DA8 • Installation and Operation

2-5

Furniture mounting

Mount the 1U high, half-rack width unit under a desk or
podium using the optional Extron MBU 125 under desk
mounting kit (part #70-077-01) as follows:
1

.

If rubber feet were previously installed on the bottom of

the unit, remove them.

2

.

Secure the mounting brackets to the unit with the machine

screws provided (figure 2-2).

Figure 2-2 — Under-desk mounting the unit

3

.

Hold the unit with the brackets attached against the

underside of the table or other furniture. Mark the location

of the screw holes of the bracket on the mounting surface.

4

.

Drill four pilot holes, each 3/32" (2 mm) in diameter by

1/4" deep (6.3 mm) deep in the mounting surface at the

marked screw locations.

5

.

Insert provided #8 wood screws into the four pilot holes.

Tighten each screw into the mounting surface until just less

than 1/4" (6.3 mm) of the screw head protrudes.

6

.

Align the mounting screws with the slots in the brackets

and place the unit against the surface, with the screws

through the bracket slots.

7

.

Slide the unit slightly in or out, then tighten all four screws

to secure the unit in place (figure 2-2).

Through-desk mounting

Mount the 1U high, half-rack width unit through a desk or
podium using the optional Extron MBD 129 through desk
mounting kit (part #70-077-02) as follows:
1

.

If rubber feet were previously installed on the bottom of

the unit, remove them.

2

.

Secure the brackets to the unit with the provided

machine screws (figure 2-3). Leave the screws slightly loose.

Figure 2-3 — Through-desk mounting the unit

3

.

Hold the unit and brackets on the underside of the surface

to which you are mounting the device and mark the four

screw holes and the table material to be removed.

4

.

Remove the table material. Test the fit by inserting the

front of the device through the hole. If necessary, use a

rasp or coarse file to enlarge the hole.

5

.

Drill four pilot holes, each 3/32" (2 mm) in diameter by

1/4" deep (6.3 mm) deep, in the locations that you marked

in step 3.

6

.

Using the provided #8 four wood screws, attach the

brackets to the mounting surface.

Advertising