EARTHSTONE OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS---U.L. LISTED

16

IMPORTANT: PLEASE READ

FOR GAS FIRE OR GAS/WOOD COMBINATION OVENS ONLY
Combustion air intake procedures and installation


Proper installation:

Roof

False Ceiling

Air flow

Air flow

24”x24” opening needed for
combustion air. Only one intake
should be installed located in the
front or back of oven.

Gas Burner system

Air flow

Roof

False Ceiling

Air flow

Air flow

24”x24” opening needed
for combustion air. Only
one intake should be

Gas Burner system

Air flow

Improper Installation:

1) No air intake opening for burner

Roof

Ceiling

Air flow

Air flow

Air flow

Blocked air intake

In this case a 24”x24” opening will be needed for proper air combustion.