Technical details – Electrolux EDB 874 User Manual

Page 41

Advertising
background image

Loading Info:

Grill Burner

Natural Gas

L.P. Gas

Heat Input

2.8kW (9554 Btu/h)

2.8kW 201 g/h

Injector Marking

123

089

Top Oven*

Heat Input

1.7kW (5800 Btu/h)

1.7k/W 122 g/h

Injector Marking

095

Flame Supervision Device

Diamond 'H' GSD 100/48

Diamond 'H' GSD 100/49

Thermostat

Sourdillon 63503/982

Sourdillon 64063/982

Thermostat By-Pass Marking

Fixed Internal

Fixed Internal

Main Oven

Heat Input

1.7kW (5800 Btu/h)

1.7kW 122 g/h

Injector Marking

095

Flame Supervision Device

Diamond 'H' GSD 100/28

Diamond 'H' GSD 100/30

Thermostat

Diamond 'H' 1100 - 122/B2 Diamond 'H' 1100 - 123/B2

Thermostat By-Pass Marking

74

79

Oven Light:

0.05kW

Control Cooling Fan

0.020kW

Timer:

0.005kW

Height:

Appliance 760 mm Installed 720 mm

Width:

593 mm

Depth:
(excluding handles and knobs)

550 mm

Weight:

49kg

Connection:

Gas

Rear top right hand side of appliance Rc½ (½" B.S.P.
Female



Electric

230/240 Volt A.C. 50Hz Mains 3 core cable and moulded

plug fused to 3 amps.

* Cannot be used at the same time as the grill burner

IMPORTANT - SAFETY REQUIREMENTS

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations
Current Editions. Detailed recommendations are contained in the following British Standard Codes of
Practice - BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'.

PROVISION FOR VENTILATION

This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with the current installation regulations. Particular attention shall be given to
the relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2
Current Edition. All rooms require an openable window or equivalent and some rooms will require a
permanent vent as well. For room volumes up to 5m³ an air vent of 100cm² is required: for room
volumes between 5m³ and 10m³ an air vent of 50cm² is required. If the room has a door that opens
directly to the outside, no air vent is required. For room volumes that exceed 11m³ no air vent is
required. If there are other fuel burning appliances in the same room, BS.5440: Part 2 Current Edition
should be consulted to determine the requisite air vent requirements.
Prolonged intensive use of the appliance may call for additional ventilation, for example opening a
window, or more effective ventilation, for example increasing the level of mechanical ventilation where
present.

41

TECHNICAL DETAILS

Advertising