Ei169 DataSht RevA

Model

Ei 169

Complete smoke alarm system

Includes high intensity strobe, smoke alarm and
vibration pad

Rechargeable battery back up

Test button

Continuous monitoring of wiring

Interconnectable to other Ei alarms

Auxiliary sockets

Low power cell warning

Complies with BS415:1990 electrical safety

5 year guarantee


Product Description

The Ei169 is a complete smoke alarm system designed
for the deaf and hard of hearing and can be selected with
either optical or ionisation smoke alarms. For an
ionisation smoke alarm, the system includes the Ei173
control panel, Ei174 vibrating pad and Ei151TL ionisation
smoke alarm (with Ei172 pattress) and has the part
number Ei170. For an optical smoke alarm version the
Ei151TL is replaced with an Ei156TL optical smoke
alarm, and the part number is Ei171

The Ei173 control panel includes a high intensity Xenon
strobe, a sealed lead-acid rechargeable battery for
standby use in the event of mains failure and all the
required circuitry to connect to the smoke alarm and
Ei174 vibrating pad

The Ei173 control panel also incorporates a Test button
and circuitry to continuously monitor the system wiring

The Ei174 vibrating pad is designed to be placed under
the mattress or pillow to wake people who fail to respond
to the strobe alarm

Up to 11 other smoke/heat alarms can be interconnected
to the master smoke alarm. In the event of mains failure
the rechargeable battery in the panel will power the
system for one week.

Operation

The green indicator will illuminate to show mains
power is present

The red indicator will flash once every second to
show that the mains supply is off and the system is
running on battery backup power

The red indicator will go off as the battery becomes
depleted (with mains off)

The slide switch on the control panel disconnects
mains and battery power from the control panel and
extinguishes both LED indicators

The “Test” button will check the strobe, vibration pad
and panel

When the smoke alarm is activated, the Ei173
control panel will flash the strobe at 1Hz and
activate the vibrating pad

The interconnect wiring from the smoke alarm to the
control panel is monitored so that if the smoke alarm
is not connected or if it is open/short circuit, then the
strobe will flash and the vibrating pad will turn on

An auxiliary socket allows the connection of an extra
strobe or vibrating pad

MAINS POWERED 230V~

For the deaf and hard of hearing