Enviro HORIZONTAL VENT KIT 50-1235 User Manual

Enviro Fans

Advertising
background image

Horizontal Vent Kit

50-1235

KIT COMPONENTS:

Quantity

Description

Quantity

Description

1

Horizontal direct vent termination cap

4

Wire spacers

1

Flue collar adapter

1

4 oz tube Mill-Pac Sealant

1

Wall thimble

1

4 oz tube RTV silicone

1

5’ (190 cm) length of Ø4” (10 cm) double walled fl ex pipe

12

9

/

16

” tech screws

1

5’ (190 cm) length of Ø6⅝” (10 cm) double walled fl ex pipe

8

1½” wood screws

Please ensure that all components are supplied with this kit. If components are missing or have been damaged,

contact your dealer, distributor, or courier company. Do not attempt the installation if components are missing

or damaged.

INSTALLATION INSTRUCTIONS:

Figure 1

Please read and understand these instructions before installing. Failure to follow these

instructions carefully could cause property damage or personal injury.

For use with Haven & Retreat Direct Vent fi replaces.

10"

(254mm)

10"

(254mm)

Wire

spacers

Figure 2

1. Plan your installation and clearances to combustibles. Decide on a location

for the unit that will meet any or all local code requirements. Refer to the

sections in your owner’s manual on where to locate your stove.

2. Set the appliance in the desired location. Determine if any wall studs,

electrical wiring, or plumbing pipes are in the way of the venting system

as it passes through the exterior wall. The fi replace location should be

adjusted if obstructions are found in the wall.

3. Project a line from the center point of the fl ue

outlet upward and outward to the desired fl ue

outlet location on the exterior wall. Using this

center point, scribe a 10” (25.4 cm) hole or

square on the wall. Cut the hole out on both

the interior and exterior wall surfaces.

4. Frame the hole as shown in Figure 1.
5. Trim the Wall Thimble to match the wall thickness as necessary. Install the wall

thimble and secure it to the inner wall frame using four (4) 1½” wood screws.

6. Apply a bead of Mill-Pac Black sealant to the new Ø4” (10 cm) by 5” (12.5 cm)

provided fl ue collar adaptor. Press the fl ue collar into the fl ue outlet of the

fi replace so that the Mill-Pac seals the fl ue collar to the fl ue outlet.

7. Stretch both the Ø4” (10 cm) fl ex vent and the Ø6⅝” (16.25 cm) fl ex intake

liner to the length needed to ensure the fl ex can be easily connected to the vent

terminal.

8. Slide the Ø6⅝” (16.25 cm) fl ex intake liner over the fl ex vent. Install four (4)

wire spacers around the fl ex pipe. Ensure the wire spacers are positioned at

either end of the pipes, and at each end of any elbows in the liners (refer to

Figure 2 and 3).

Advertising