Design Spot 250 Pro™

©Elation Professional® 27 Design Spot 250 Pro™

“XX M” Where XX represents the hold time before lamp shut down.

8.3.6 Lamp On at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is sensed

inside the head by the on-board CPU. The lamp is shut down to prevent damage to the

lamp and avoids possible internal damage to the head. This function sets the minimum

temperature for lamp re-strike after the lamp has been automatically shut off.

8.3.7 Lamp Off at Temp.

The fixture is designed to shut the lamp off when an excessive temperature is sensed

inside the head by the on-board CPU. The lamp is shut down to prevent damage to the

lamp and avoids possible internal damage to the head. This function sets the maximum

internal operating temperature of the head before the lamp will automatically be shut

down. This function can be set to activate at an internal temperature between 80° C and

139° C. Inside temperatures below 90° C are not critical. Temperatures above 90° C

should lead to the lamp being switched off. Please note that the outside temperature

should not exceed 45° C.

8.4 Personality:

8.4.1 Status setting

Address via DMX - This function allows the DMX address to remotely be adjusted

from a DMX console. This setting requires special settings for both the controller and

the fixture. RDMX is on by default. For operational instructions please see Section

10/Page 33 of this manual “Remote DMX addressing.”

No DMX Status – This function dictates how the fixture will function if it looses DMX

signal during normal operation. The default function is set to hold, in which the

fixture will lock into the last DMX signal it received and remain in that position until it

is turned off or begins receiving a new DMX signal. If the fixture is turned on

without any DMX signal, the fixture will automatically go in to sound-active mode.

Available settings are: “Close” – Shutter flags will close. “Hold” – Fixture will remain