Ericsson LBI-39055 User Manual

Page 8

Advertising
background image

LBI-39055

8

RS422x-x board configuration is:

Address Switches A3-A9

All On

(RS422AT-P)

Address Switches A3-A9

All Off

(RS422I-P)

Interrupt Jumper

IN4

LD GND Jumper

In

LD Jumper

In

DX Jumper

In

SX Jumper

Out

HDX Jumper

Out

FDX Jumper

In

SLOT 8 Jumper

Out

(RS422AT-P)

-BIAS and +BIAS

Out

(RS422I-P)

Configuration for the 3PXOCC1A board is:

Address Switches (S1)

All Off

Interrupt Jumper

IRQ4

Jumpers JP12

JP15

Upper Position

Jumpers JP16

JP17

Lower Position

If any other RS-422 plug-in serial board is used the

following board configuration must be used:

COM Port

COM1

Port Address

3F8

Interrupt

IRQ4

See Figure 8A or the manufacturer's documentation for

COM port connector pin-out details. Interconnect the
control data connections between the PC and the
appropriate CEC/IMC Data Concentrator Card as required.
Shielded pairs are recommended.

Remote Console Interconnections Via A 4-Wire Modem

When the C3 Maestro is installed at a remote location

from the CEC/IMC, serial control data must be routed via
RS-232 connections and 4-wire modems. Since the C3
Maestro requires a dedicated or continuous serial link (non-
dial-up), a 4-wire leased line (or equivalent) meeting 3002
data grade specifications must be employed between the
CEC/IMC and the C3 Maestro in a remote console
installation.

Figure 8B shows typical control data interconnections

for a remote console installation using RS-232 connections
and full-duplex 4-wire modems. At the CEC/IMC Data
Concentrator Card, RS-232 connections are made at J13,
not J12. Observe all notes listed in the figure if wiring an
installation of this type
. Recommended modem settings
are:

Modem Options

DCE Rate = 9600

Originate/Answer = Originate (CEC/IMC modem)
Originate/Answer = Answer (C3 Maestro modem)

V.32 Fast Train = Enabled

Auto Retrain = Enabled

Internal/External Clock = Internal

Dial-Up/Leased Line = Leased

2-Wire/4-Wire = 4 Wire

TX Level = (as required; use -15 dBm if line loss is 0 dB)

Dial Backup = Manual

Loop Back Time = 15 minutes

Dial Line = RJ11

Line Current Disconnect = Long

Long Space Disconnect = Enabled

V.22 Guard Tone = Disabled

MNP Options

MNP Protocol = Enabled

Auto Fallback = Enabled (or Normal)

Flow Control = CTS Only

XON/XOFF Pass Through = Enabled

Data Compression = Disabled

Inactivity Timer = Off

Break Control = 5

DTE Options

Synchronous/Asynchronous Data = Asynchronous

DTE Rate = 9600

Character Length = 8 Bits

Parity = None

Commanded Dialer = Asynchronous

AT Command Set = Disabled

DTR Control = Disabled

DSR = Forced High

DCD = Normal

CTS = Forced High

DTE Fallback = Disabled

Options = Retained At Disconnect