Repairs, Environmental protection, Technical specifications – Elektra Beckum Compressor Pump Basic 265 User Manual

Page 6: English

Advertising
background image

10

ENGLISH

Hose connection between compres-
sor and air tool leaky.

Check air hoses, replace defec-
tive parts if necessary.

Danger!
Repairs to power tools must be

carried out by qualified electricians
only!

Power tools in need of repair can be sent
to one of the adresses listed on the sec-
ond-last page.

Please attach a description of the fault to
the power tool.

The machine’s packaging can be 100 %
recycled.

Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.

These instructions are printed on chlo-
rine-free bleached paper.

7.

Repairs

8.

Environmental Protection

9.

Technical Specifications

Suction capacity

l/min

235

Free air delivery (volume flow rate)

l/min

125

Filling rate

l/min

145

Working pressure (compression end pressure)

bar

8

Pressure vessel volume

l

50

No. of air outlets

2

Pump model

F 245

No. of cylinders

1

Motor speed

min

-1

2850

Motor capacity

W

1.5

Supply voltage (50 Hz)

V

230

Rated current

A

6.8

Fuse protection min.

A

10 (time-lag)

Degree of protection

IP 20

Max. overall cable length when using extension cables:
– at 3 x 1.0 mm

2

lead cross section

– at 3 x 1.5 mm

2

lead cross section

– at 3 x 2.5 mm

2

lead cross section

m
m
m

10
25
25

Dimensions length x width x height

mm

905 x 410 x 690

Weight

kg

25

Sound pressure level at 1 m max.

dB (A)

88 ± 3

Advertising