Troubleshooting Checklist

Troubleshooting

4-5

4.2

TROUBLESHOOTING CHECKLIST

If the module is not working properly, refer to

Table 4-2

for a checklist of problems, possible

causes, and recommended actions to resolve the problem.

Table 4-2

Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

All LEDs are
OFF.

Loss of power.

Ensure that the module was installed
properly according to the installation
instructions in

Chapter 3

, and that the host

chassis is powered properly.

No Local
Management
Password screen.

Autobaud is enabled, but
the baud rate has not yet
been detected.

Press ENTER (RETURN) (may take up to
four times).

Incorrect terminal setup.

Refer to the MATRIX E5 Series Modules
Local Management User’s Guide
for proper
setup procedures.

Improper console cable
pinouts.

Refer to

Appendix A

for proper COM port

pinouts.

Corrupt firmware image,
or hardware fault.

If possible, attempt to download the image to
the module again. Refer to

Section B.2

for

instructions to clear NVRAM.

Cannot navigate
beyond Password
screen.

Improper Community
Names Table.

1. Refer to the MATRIX E5 Series Modules

Local Management User’s Guide for the
Community Names Table setup.

2. If the Community Names have been

forgotten, refer to

Section B.2

for

instructions on how to set the mode switch
to reset the Community Names to their
default values.