Change of door opening direction, Electrical connection, Electrical requirements – Electrolux A 75108 GA3 User Manual

Page 9

Advertising
background image

9

Change of door opening direction

Should the setting-up place or handling demand it, door-

opening direction can be refitted from the right hand side

to the left hand side.
Following operations are to be done on the basis of figures

and explanations:

Pull out the plug from the mains socket.
Tilt back the appliance carefully so that the

compressor can not touch the floor. It is

recommended to ask another person for help, who can

keep the appliance at this position safely.
Unscrew the adjustable feet situated on both sides (2

pieces), in addition the screws fixing the lower door

holders (3 pieces) respectively the screw on the other

side.

Take off the freezer door by pulling it slightly

downwards.
Unscrew the top door hinge pin of the refrigerator

then screw it back on the other side.
Fit the freezer door on the upper door hinge pin.
Insert over the pin in the lower door holding plate in

the direction of the arrow.

Fix the plate on the other side leaving the position of

the door unchanged.

Then screw in the one screw in the place set free on

the other side as well as the adjustable feet (2

pieces) and stand upright again.
Place over the handles on the other side and put the

plastic covering pins supplied in the plastic bag of this

instruction book into the vacant holes.
Place the appliance back into its location, set it level

and plug it into the mains socket.

In case you do not want to perform the procedures above,

call your nearest Service Force Centre. Technicians will

accomplish the refitting expertly for a charge.

Electrical Connection

Any electrical work

required to install this

appliance should be carried out

by a qualified electrician or

competent person. This appliance

must be earthed.
The manufacturer declines any

liability should these safety

measures not be observed.

Electrical Requirements

Before switching on, make sure the electricity supply

voltage is the same as that indicated on the appliance

rating plate.
The appliance is supplied with a 13 amp plug fitted. In the

event of having to change the fuse in the plug supplied, a

13 amp ASTA approved (BS 1362) fuse must be used.

Should the plug need to be replaced for any reason. The

wires in the mains lead are coloured in accordance with

the following code:
Green and Yellow:

Earth

Blue:

Neutral

Brown:

Live

The wire coloured green and yellow must be connected to

the terminal marked with the letter “E“ or by the earth

symbol

or coloured green and yellow.

The wire coloured blue must be connected to the terminal

“N“ or coloured black. The wire coloured brown must be

connected to the terminal marked “L“ or coloured red.

GB

Advertising