Epson SED 1520 Series User Manual

Page 32

Advertising
background image

SED1520 Series

EPSON

2–23

SED1520

Series

AC Characteristics

• MPU Bus Read/Write I (80-family MPU)

Ta = –20 to 75 deg. C, V

SS

= –5.0 V

±

10% unless stated otherwise

Rating

Parameter

Symbol

Condition

Unit

Signal

Min.

Max.

Address hold time

t

AH8

10

ns

A0, CS

Address setup time

t

AW8

20

ns

System cycle time

t

CYC8

1000

ns

WR, RD

Control pulsewidth

t

CC

200

ns

Data setup time

t

DS8

80

ns

Data hold time

t

DH8

10

ns

D0 to D7

RD access time

t

ACC8

90

ns

C

L

= 100 pF

Output disable time

t

CH8

10

60

ns

Rise and fall time

t

r

, t

f

15

ns

(V

SS

= –2.7 to –4.5 V, Ta = –20 to +75

°

C)

Rating

Parameter

Symbol

Condition

Unit

Signal

Min.

Max.

Address hold time

t

AH8

20

ns

A0, CS

Address setup time

t

AW8

40

ns

System cycle time

t

CYC8

2000

ns

WR, RD

Control pulse width

t

CC

400

ns

Data setup time

t

DS8

160

ns

Data hold time

t

DH8

20

ns

D0 to D7

RD access time

t

ACC8

180

ns

C

L

= 100 pF

Output disable time

t

CH8

20

120

ns

Rise and fall time

t

r

, t

f

15

ns

t

CC

t

CYC8

t

AW8

A0,CS

WR,RD

D0 to D7

(WRITE)

D0 to D7

(READ)

t

f

t

r

t

DS8

t

AH8

t

DH8

t

OH8

t

ACC8

Advertising