Rear panel connectors & switches, Installation and operation, cont’d, Rear panel connectors and switches – Extron Electronics SCP_AAP A User Manual

Page 7

Advertising
background image

SCP/AAP A, SCP 200, SCP 250 • Installation and Operation

SCP/AAP A, SCP 200, SCP 250 • Installation and Operation

Installation and Operation, cont’d

2-5

Rear Panel Connectors
and Switches

2-4

SCP 200

SW13

J1

J2

1

1

8
7
6
5
4
3
2
1

1

2

3

SCP 250

SW13

J2

J1

1

1

8

7

6

5

4

3

2

1

1

2

3

SCP/AAP A

SW1
1

J3

J2

1

1

2

3

4

5

6

7

8

1

2

3

1

&

2

Communications connectors

— Use these connectors to

connect SCPs together and to connect them to the switcher.
Both connectors function the same way, so they are
interchangeable.

Plug one end of an Extron Comm-Link cable into one of these
3.5 mm, 5-pin captive screw connectors, and plug the other end
into the system switcher (or to the next SCP closer to the
switcher, if daisy chained).

If this SCP is at the end of a daisy chain of SCPs, do not use the
other connector. If this SCP is in the middle of a chain of SCPs,
plug one end of a Comm-Link cable into the second captive
screw connector, and plug the other end into the next SCP
further away from the switcher.

3

DIP switches

— Set these switches to indicate what model of

system switcher the SCP is attached to. For the SCP/AAP A,

these DIP switches also identify which input
will be selected when the “Show Me” button
is pressed.

1, 2, 3, 4 — Input number identification

— See the table below

for the appropriate settings for each SCP address.

5, 6, 7 — Not used

— Keep these set to the closed/up position.

8

Switcher model identification (all models)

Closed/up — System 7SC
Open/down — System 5cr Plus

1

2

3

4

5

6

7

8

0

0

0

0

0

0

0

*

1

1

0

0

0

0

0

0

*

2

0

1

0

0

0

0

0

*

3

1

1

0

0

0

0

0

*

4

0

0

1

0

0

0

0

*

5

1

0

1

0

0

0

0

*

6

0

1

1

0

0

0

0

*

7

1

1

1

0

0

0

0

*

8

0

0

0

1

0

0

0

*

9

1

0

0

1

0

0

0

*

10

0

1

0

1

0

0

0

*

11

1

1

0

1

0

0

0

*

12

0

0

1

1

0

0

0

*

13

1

0

1

1

0

0

0

*

14

0

1

1

1

0

0

0

*

15

1

1

1

1

0

0

0

*

16

DIP Switch Number

SCP

Address

SCP

Address

*For switch 8

0

= System 7SC

1

= System 5

cr

Plus

Switch 8

must

be set for

all

SCPs.

For all switches

0

= closed (up)

1

= open (down)

SCP DIP switch assignments

3

4

1

2

7

8

5

6