Ei420

Technical Specification

Supply Voltage:

230V AC, 50Hz

Battery Back-up:

Rechargeable Lithium cells

Interconnect:

RadioLINK - Up to 12 RadioLINK
units
Hard-wired - Up to 12 Ei261ENRC/
Ei261DENRC alarms


RF Signal Range

1

:

150 metres in free space

RF Frequency:

868MHz band (1% duty cycle)

RF Power:

+5dBm


Power Indicator:

Green (constant) – power on

Red (flashing) – low battery


Temperature Range:
0ºC to 40ºC

Humidity Range:

0% to 95% R.H.


Dimensions:

140mm x 26mm


Weight:

180g


Guarantee:

5 year (limited)


Approvals:

RF performance to EN300220-3
EMC performance to EMC 301489-3

CE certified

Specifications are subject to change

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Phone.

+353 (0)61 471277

Fax.

+353 (0)61 471053

E-mail.

[email protected]

Web.

www.eielectronics.com

1.

Any obstructions of any sort will result in a reduction in range from the

free space specification. As such, the actual range will vary depending
on installation.