Maintenance, Warning – Echo PB-620ST User Manual

Page 15

Advertising
background image

15

P

ower

B

lower

o

Perator

'

s

M

anual

m

aIntenanCe

WARNING

Moving parts can amputate fingers or cause severe injuries. Keep hands, clothing and loose objects away from all

openings. Always stop engine, disconnect spark plug, and make sure all moving parts have come to a complete

stop before removing obstructions, clearing debris, or servicing unit. Allow unit to cool before performing service.

Wear gloves to protect hands from sharp edges and hot surfaces.

Your ECHO blower is designed to provide many hours of trouble-free service. Regular scheduled maintenance will help

your blower achieve that goal. If you are unsure or are not equipped with the necessary tools, you may want to take your

unit to an ECHO Service Dealer for maintenance. To help you decide whether you want to DO-IT-YOURSELF or have

the ECHO Dealer do it, each maintenance task has been graded. If a task is not listed, see your ECHO Dealer for repairs.

skIll

levels

Level 1 = Easy to do. Common tools may be required.

Level 2 = Moderate difficulty. Some specialized tools may be required.

ECHO offers REPOWER

TM

Maintenance Kits and Parts to make your maintenance job easier.

COMPONENT / SYSTEM

MAINTENANCE

PROCEDURE

REQ'D

SKILL

LEVEL

DAILY OR

BEFORE USE

EVERY

REFUEL

3 MONTHS

OR 90

HOURS

YEARLY

600 HOURS

Air Filter

Inspect/Clean

1

I / C *

R *

Choke Shutter

Inspect/Clean

1

I / C

Fuel Filter

Inspect/Replace

1

I *

I / R *

Fuel Cap Gasket

Inspect/Replace

1

I *

R *

Fuel System

Inspect/Replace

1

I (1) *

I (1) *

Spark Plug

Inspect/Clean/Replace

1

I / C / R *

Cooling System

Inspect/Clean

2

I / C

Muffler Spark Arrestor

Inspect/Clean/Replace

2

I / C / R *

Cylinder Exhaust Port

Inspect/Clean/Decarbon

2

I / C

Recoil Starter Rope

Inspect/Clean

1

I / C *

Screws/Nuts/Bolts

Inspect/Tighten/Replace

1

I *

MAINTENANCE PROCEDURE LETTER CODES: I = INSPECT, R = REPLACE, C = CLEAN
IMPORTANT NOTE
- Time intervals shown are maximum. Actual use and your experience will determine the
frequency of required maintenance.
MAINTENANCE PROCEDURE NOTES:
(1) Low evaporative fuel tanks DO NOT require regular maintenance to maintain emission integrity.
* All recommendations to replace are based on the finding of damage or wear during inspection.

maIntenanCe