Software and accessories – Eaton Electrical CA04801001E User Manual

Page 12

Advertising
background image

March 2008

12

For more information visit: www.eaton.com

CA04801001E

Operator Interface Products
HMi
Operator Interface

Software and Accessories

Table 12. HMIEC0806/HMIEC1612 Function Specifications

M1000, M1001, M1002, M1003, M1020, M1021, M1022, M1067, M10068, and M1161 are the
special auxiliary relays (special M).

Item

Specifications

Remark

Control Method

Stored program, cyclic
scan system

I/O Processing Method

Batch I/O (refresh)

Immediate refresh command available only
with I/O of the MPU

Execution Speed

Basic command (30 us)

Application command (30 ~ hundreds us)

Program Language

Commands + Ladder
Diagram + SFC

Step commands included

Program Capacity

999 Steps

Built-in EEPROM

Commands

Basic commands: 32
(including the STL
commands)

Application commands: 59

Step Relay
(Latched)

General Step
Point

128 Points

S0 ~ S127

Auxiliary
Relay

General

1024 Points

M0 ~ M511, M768 ~ M999, 744 points;
M1000 ~ M1279, 280 points

Latched

256 Points

M512 ~ M767

Timer

Digital

64 Points

T0 ~ T63 (100 ms time base)

63 Points

T64 ~ T126 (10 ms time base)

1 Points

T127 (1 ms time base)

Counter

General

112 Points

C0 ~ C111

Latched

16 Points

C112 ~ C127

32 bit

13 Points

C235,C236,C237,C238,C241,C242,
C244,C246,C247,C249,C251,C252, C254
(all of them are latched type)

Data
Register

General

408 Points

D0 ~ D407

Latched

192 Points

D408 ~ D599

Pointer

P

64 Points

P0 ~ P63

Index
Register

E / F

2

E, F

Constant

Decimal K

16 bit: -32768 ~ +32767

32 bit: -2147483648 ~ +2147483647

Hexadecimal H 16 bit: 0000 ~ FFFF

32 bit: 00000000 ~ FFFFFFFF

Self Diagnosis / Protection

I/O check, system execution timeout check, invalid command check,
program check and password settings

Monitor / Debug

Program execution time display, bit / word, device settings

Advertising