Digital rx power packs, Digital as – Elinchrom 300RX User Manual

Page 25

Advertising
background image

25

Digital RX Power Packs

Digital 1200 RX

Digital 2400 RX

Joule / Ws

1200

2400

F-stop 1m ISO 100; 1 / 125 s; Reflector 48°

128

180

Recycling min. / max. 230 V / fast

0.24 – 1.0 s

0.4 – 1.9 s

Recycling min. / max. 230 V / slow

0.35 – 1.9 s

0.55 – 3.6 s

Flash duration t 0.5, max. power, 2 x A heads

1/3400 s

1/1700 s

Flash duration t 0.5, max. power, 1x Digital S head

1/1200 s

1/600 s

Power range in Ws, 6 f-stop

37 – 1200

75 – 2400

Computer Interface

All models

Socket for EL-Skyport & Remote control

All models

Sync voltage

5 V

Voltage stabilization

+ - 0.5%

Fan cooled

All models

Modelling lamp, proportional / free / off

All models

Charge ready beep / on-off

All models

Photocell / on-off

All models

ADF, auto dump function

All models

Dimensions in cm

22 x 13 x 23

22 x 13 x 32

Lightweight in kg

4.6

6.6

Code 230 V 50 - 60 Hz

10256

10258

Code 115 - 130 V 50 - 60 Hz

10255

10257

Digital AS

Digital 3000 AS

Digital 1500 AS

Joule / Ws 230 V min. / max.

62 - 3000

31 - 1500

F-stop 1m ISO 100; 1 / 250 s; Reflector 48° 230 V

180.3

128.6

Recycling rapid/medium, max. power 230 V

3.5 s / 4.5 s

1.5 s / 2.1 s

Flash duration t 0.5 max. power, 3 S heads connected

1/1150 s

1/1850 s

Memory

Retains last setting

IR Remote control

All functions, 8 channel settings

Power range

6.6 f-stop

Total power asymmetry

56 individual power settings for each head

Sync voltage

12 V

Ready beep on / off

All modells

Photocell on / off

All modells

Dimensions in cm

49 x 14 x 32

49 x 14 x 27

Weight in kg

11.65

8.6

Code 230 V 50 - 60 Hz

10254

10248

Code 115 - 130 V 50 - 60 Hz

10253

10247

Note: Tolerances of specifications and components conform to IEC and CE standards. Technical data subject to change. No guarantee for misprints.
The listed values can differ due to tolerances in components, or measuring instruments.

Advertising