Vent parts and terminal clearances, Venting, Initial installation – Enviro C-10791 User Manual

Page 16

Advertising
background image

16

Initial Installation

QUALIFIED INSTALLERS ONLY

V

ENT

P

ARTS

AND

T

ERMINAL

C

LEARANCES

:

The Sherwood Home Collection of fireplaces have been tested and certified for use with SIMPSON

DURAVENT TYPE GS PIPE FOR GAS STOVES. SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT

SYSTEM” and SELKIRK “METALBESTOS MDV VENT SYSTEM” kits are available for horizontal venting.

When using Simpson Duravent, it is recommended that, before installation, a bead of RTV High

Temperature Silicone should be applied to each outer vent joint, and Mil-Pac to each inner joint. When

planning an installation, it will be necessary to select the proper length of vent pipe for the particular

requirements.

V

ENTING

:

This fireplace has been tested and certified for use with SIMPSON DURAVENT TYPE GS PIPE FOR GAS

STOVES, SECURITY CHIMNEY’S “SECURE VENT DIRECT VENT SYSTEM” and SELKIRK “METALBESTOS

MDV VENT SYSTEM”
A 1 inch (2.5 cm) clearance to combustibles must be maintained around any vertical vent pipe. Around

a horizontal vent pipe, the clearance to combustibles should be 2 inches (5 cm) above and 11⁄2 inches (4

cm) on the sides and bottom. When combustible materials are directly above a 90° elbow, 3 inches (7.6

cm) of clearance are necessary. A 10 inches (25 cm) x 10 inches (25 cm) frame will assure the proper

support and spacing for the vent pipe as it passes through the wall. Installations in Canada require that a

wall thimble be used for passing through walls and ceilings, see Figure 21. All sealing and vapour barriers

must comply with local building codes.

Table 3: Vent part numbers.

Simpson Duravent (SD), Selkirk (SEL), and Security Chimneys (SC), must state if galvanized or black wanted, PART NUMBERS:

SD

SEL

SC

Description

SD

SEL

SC

Description

908

4DT-6

SV4L6

6” pipe length

911

11” to 14 5/8” pipe, adjustable

907

4DT-9

9” pipe length

4DT-AJ

4” to 10” pipe , adjustable

906

4DT-12

SV4L12

12” pipe length

SV4LA12 11⁄2” to 12” pipe , adjustable

904

4DT-24

SV4L24

24” pipe length

943

4DT-AF6

Flashing, 0/12 to 6/12 roof pitch

903

4DT-36

SV4L36

36” pipe length

943S

4DT-AF12

Flashing, 7/12 to 12/12 roof pitch

902

4DT-48

SV4L48

48” pipe length

SV4FA

Flashing, 1/12 to 7/12 roof pitch

945 4DT-EL45 SV4EBR45 45° elbow, black

SV4FB

Flashing, 8/12 to 12/12 roof pitch

990 4DT-EL90 SV4EBR90 90° elbow, black

943F

SV4F

Flat flashing

950

4DT-VS

SV4VS

Vinyl siding standoff/

sheild

980

4DT-VC

SV4CGV

Vertical termination

942

4DT-WT

SV4RSN

Wall thimble

991

4DT-HVC

High wind vertical termination

953

4DT-SC

SV4FC

Storm collar

984

4DT-HC

SV4CHC

Horizontal square termination

963

4DT-FS

SV4BF

Fire stop

985

4DT-HHC

High wind horizontal termination

988 4DT-WS/B

SV4BM

Wall strap/support/band

978

4DT-VKC

SV0FAK

Vertical termination kit

970

4DT-HKA

SV0SHK

Horizontal termination kit

(SD: Basic Kit, SEL: Kit A,

SC: Standard Kit)

971

4DT-HKB

SV0SHK2 Horizontal termination kit

(SD: Kit A, SEL: Kit B, SC: Kit)