Electrical system for thermostat, Initial installation, Qualified installers only i – Enviro C-10791 User Manual

Page 23

Advertising
background image

Initial Installation

QUALIFIED INSTALLERS ONLY

I

NSTALLATION

O

F

E

LECTRICAL

W

IRING

F

OR

T

HE

O

PTIONAL

F

AN

K

IT

:

Figure 31. Wiring Diagram For Gas Valve.

COOL / HEAT
PROGRAM

DOWN

UP

70 ° F

70 ° F

ON

OF

F

Optional

Remote

Control

ON/OFF/Remote

Thermostat Switch

Purple

Thermocouple

Blue

Thermopile

Grey

Inlet

Pressure

Tap

Gas Control

Valve

Manifold

Pressure Tap

Pilot Adjustment

Screw

Optional

Wall Switch

Optional

Thermostat

Wire Size

Max. Length

14 gauge

100 ft (30.48 m)

16 gauge

60 ft (18.29 m)

18 gauge

40 ft (12.00 m)

20 gauge

25 ft (7.62 m)

22 gauge

18 ft (5.49 m)

Table 5. Recommended Thermostat

Wire Size.

23

Figure 30. Install Electrical Outlet Into DV36.

The electric box/outlet must be hard wired to

the bottom left (or right if the gas line is to

come in on the left) of the unit if you plan to

install the Optional Fan Kit in the future.
Refer to local electrical bylaw for proper

installation. In the absence of local codes,

with the current CSA C22.1 Canadian Electrical

Code Part 1, Safety Standards For Electrical

Installations, or The Current National Electrical

Code ANSI / NFPA 70 in the US.

E

LECTRICAL

S

YSTEM

F

OR

T

HERMOSTAT

:

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause

improper and dangerous operation. Verify proper operation after servicing.