Trouble Shooting

Problem

Possible Cause

Solution

Spark will not light the

pilot after repeatedly

pressing the spark ignitor

Defective piezo ignitor

• Check connections to ignitor.

• If ignitor connections are good but no spark,

replace ignitor.

Broken spark electrode

• Check for broken ceramic insulation, replace

electrode if broken.

Misaligned spark electrode • If spark is not arcing from electrode to pilot,

loosen the screws on the pilot base adjust and

tighten.

Pilot will not remain lit

Problem with

thermocouple circuit

• Check for proper connection of the thermocouple

to the rear of the valve. If loose, fully tighten.

• Check pilot for full flame impingement around

thermocouple. If flame is too small, check gas

pressure, adjust pilot rate screw, check pilot

head for damage.

• Check thermocouple voltage at valve. It

must be greater than 5 mV. If low, replace

thermocouple.

Air in gas line (pilot dies

while knob is depressed)

• Bleed line.

• Check gas line pressure.

• Contact dealer.

Burners will not remain

lit

Problem with thermopile

circuit

• Check gas line pressure .

• Check for flame impingement on thermopile. If

low, see “Pilot will not remain lit”.

• Check thermopile for minimum of 300 mV when

burner is switched on.

• Check wiring to thermostat for breaks.

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

Improper vent

configuration

• Check vent configuration with manual.

Terminal may be

recirculating flue gases

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation** Clean as

needed.

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

Flames are burning

“dirty” or sooting

Flame impingement

• Check log positioning.

• Increase primary air by opening the venturi

shutter and/or by opening the vent restrictor.

See also “Burners will not remain lit.”

Remote control doesn’t

work

Problem with the remote

• One or more of the batteries are dead. See

remote control instructions.

Problem with fireplace

• The on/off switch is turned to OFF.

• The gas control valve is turned to PILOT or OFF.

• The pilot has gone out.