Pilot light, Air shutter, Operating instructions – Enviro C-10791 User Manual

Page 7

Advertising
background image

2. Start the pilot by pressing the gas control knob and turning it to PILOT.

While holding the gas control knob in, press the piezo ignitor several times

until the pilot light starts. Hold the gas control knob in for 30 seconds.

Check that the pilot has fully engulfed the thermocouple assembly (see

Figure 3).
3. Start the main burner by turning the gas control knob to ON and then

turn the rocker switch to ON. Check that all burner ports have flame.
4. Leak test all gas joints again.

A

IR

S

HUTTER

:

The air shutter adjustment lever is centered above the controls (see Figure 4).
The air shutter allows the amount of air coming into the fireplace to be adjusted in order to accommodate

different climates and venting arrangements. Start the pilot and then the burner. Make sure the pilot

flame is burning normally and none of the burner ports are plugged. Let the fireplace burn for roughly

fifteen minutes and then examine the flames, compare the flames to Figure 40.
The ideal flame will be blue at the base and light orange above. The flames should be of medium height.

If the flames look like this, no venturi adjustment is needed. If the flames are fairly short and mostly

���� ��� � ����

���� ��� � �����

��� �������

blue, the fireplace is getting too much

air. Therefore, the air shutter should be

closed (push in) slightly until the correct

flames are achieved. Flames that are

very orange, with tall, dark, stringy tips,

are not getting enough air. Open (pull

out) the venturi until the flames clean

up. If the venturi is opened, or closed all

the way, and the correct flames cannot

be attained, turn off the gas and contact

the dealer.
Warning: Incorrect venturi adjustment

may lead to improper combustion, which

is a safety hazard. Contact the dealer if

there is any concern about the venturi

adjustment.

Figure 4. Air shutter adjustment lever.

����������

������������

Figure 3. Pilot Flame

7

Operating Instructions

P

ILOT

L

IGHT

:

1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air

out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints

with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING.