Troubleshooting procedures, Squelch checks – Ericsson LBI-38505A User Manual

Page 10

Advertising
background image

TROUBLESHOOTING PROCEDURES

SQUELCHED

UNSQUELCHED

NOISE SQ OUTPUT

U605-2

0.2 VDC

9.9V

CAS

U605-1

0.1 VDC

9.9V

RX MUTE

U605-14

0.2 VDC

9.9V

RUS

U605-13

0.2 VDC

4.9V

SQ DISABLE SW. INPUT

U606-1

0.2 VDC

9.9V

AUDIO GATE SW. CONTROL

U606-11

0.2 VDC

9.9V

If External Decoder is used (CG, DCG, Type 99, etc.), RX Mute will remain low (regardless of noise squelch output), until proper

response is decoded. RX Mute = Noise Sq Output

Decoder Output.

In above cases, Sq Disable is assumed high (9.9V). If Sq Disable is grounded, U606-10 = 0.2 Vdc, U606-11 = 9.9 Vdc and Unit

is unsquelched for all conditions.

SQUELCH CHECKS

SYMPTOM

PROCEDURE

IMPROPER SQUELCH OPERATION

Check voltages on Schematic Diagram.

Make gain and waveform checks with noise.

Make gain and waveform checks with 6 kHz signal.

Check discrete components in the squelch circuit.

Replace IC circuit U603.

LOW OR DISTORTED AUDIO

Check voltages on Schematic Diagram.

Make gain and waveform checks.

Check receiver alignment and FM -DET output.

Check Q601, Q602, Q605 and other discrete components.

SYMPTOM CHECKS Con’t.

LBI-38505

LBI-38505

9

Advertising