Eurotech Appliances Winner User Manual

Page 7

Advertising
background image

Assessing the Subscriber Site

:

2

STAGE

i.

The WINNER GSM gateway must be installed indoors:

ii.

Basement installation is not recommended, it can be done, but you must
use an external antenna

iii.

Installation in a place in which the temperatures may not exceed the

iv.

specified operating temperature range (see safety guidelines above)

v.

You should make sure that there is sufficient air movement

vi.

Installation in higher locations is preferred i.e. near windows and outer
walls

STAGE 3: Installing the system:

1 )

Inspect the package, you should see: a unit gateway, an antenna, an adapter, a

user's manual. Please note: the WINNER unit comes without the SIM card(s)!

2 )

Connect the antenna at a distance greater than 1 meter from the unit. Location of

the antenna is important in order to get best performances, thus once you turn the
power on, make sure you have best reception and clear conversation with the
unit.

3 )

Insert SIM card into the unit:

A)

In case of single channel unit, insert the SIM card in the designated slot (on

the right side panel) adjacent to the antenna connection you will see a thin

mettalic black colored drawer. Use a small pointed object such as the point of a
ballpoint pen into the little hole on the right side of that drawer/slot to open the

drawer, then insert the SIM into that drawer (SIM face up) and close the drawer
firmly.
In case of dual channel unit, there are up to four SIM card slots on the bottom side of
the unit for each module. The SIM card slots are numbered from the top down as #1,
#2, #3 and #4.

Insert SIM #1 for the first Provider, this is the default provider, the main provider.
Insert SIM #2 for the Second Provider.
Insert SIM #3 for the Third Provider
Insert SIM #4 for the Forth provider
For 'Up to 8' SIM cards 1- 4 for each module place each according to provider (no.1 to 4)
as described above.

4 )

Connect the gateway unit to a PBX telephone network or telephone line with the

RJ-11 cable (provided with unit) on the left side panel.

5 )

On the left side panel you will find the POWER socket. Connect the adapter

(provided with unit) to the electrical outlet and then to the electrical socket.

Note: The power input is 90 260 VAC and the output is 12 VDC 1.2 Amp

6 )

Wait 30 seconds for the unit to startup.

7 )

Connect a landline ordinary telephone to the RJ-11 connector (pin 3 and 4 are

used for Tip and Ring)

8 )

In case of WINNER GSM single channel unit: place an outgoing call to test the

system. If the LCD shows the number you have dialled; the device is in correct
operation mode OK. If you see the operator/ provider name on the LCD try to
make an outgoing call. You should see the number dialed on the LCD, then make
a call into the unit from another telephone, cellular or landline, you should see the
ID caller on the LCD.

Advertising