Ei Electronics Ei 405TYC User Manual

Page 21

Advertising
background image

21

RF RECEPTION

External Alarm
RF Signal:

Turns on horn without red light flashing
until it fails to receive alarm confirmation
for 11 seconds. Stops horn within 3 sec-
onds, on receipt of an "Alarm "Cancel" sig-
nal (from any unit). Receiver remains on
"continuously" for 11 seconds to check for
further alarm signals.

Length of
Program Mode:

15 minutes

Remote Test Button: Turns on test button so red light flash, I/O
(Keyfob Ei410)

line high. No RF message sent by smoke
alarm

Remote Hush:

It silences its horn for ten minutes

(Keyfob Ei410

Remote Locate:

Stops smoke alarm sounding unless it is in

(Keyfob Ei410)

local alarm itself i.e. detecting smoke

RF VISUAL INDICATOR (BLUE)

Test Button:

Blue light indicates test button pressed.

On Transmission: Blue LED lights continuously for 1.5 to 3.5

seconds while messages are being
transmitted

Low Battery
Indication:

Unit beeps and red light flashes every 40
seconds. On Ten Year battery units,
Ei405TY, blue LED also flashes every 9
seconds if radio battery is low

Size of System:

A maximum number of 32 units can com-
municate together on one system (howev-
er the range is likely to be the limiting fac-
tor in many cases)

Communication:

All units will communicate together as
shipped (units uncoded). After a unit has
been programmed it will only communi-
cate with units whose serial numbers it
has learned (i.e. is house coded)

Entering Program
Mode:

Pressing the test button three times within
1.5 seconds puts the smoke alarm in pro-
gram mode.