Operation of quick connect fittings – Elkay ERW32-1C User Manual

Page 2

Advertising
background image

97657C (REV. G - 8/03)

ERW32-1C

DESCRIPTION

28165C
28218C
28166C
28032C
23158C
26701C

34783005

35882C
66633C
36034C
30768C
35985C
35984C
35989C
35988C
35990C
30039C
50196C
66624C
70772C
66621C
70020C
66623C
30040C
36045C
70482C
70274C
70483C
35895C

1
2
3
4
5
6
7
8
9

10

11

*12

13
14
15
16
18
19
20
21
22
23
24
25
26
27
28
29
30

PART NO.

BOX - INSULATION
BASE ASSY
PANEL
PANEL - FRONT/REAR
COVER - INSULATION BOX
CABINET
WASHER - LOCK
CONTROL - COLD
CONDENSER ASSY
CSIR BOX ASSY
SOLENOID VALVE
COMPRESSOR SERVICE PAK
OVERLOAD
GASKET - TERM COVER
OVERLOAD SPRING
BALE STRAP
ELECTRICAL BOX
GROMMET - COMPRESSOR MTG
EVAPORATOR ASSY
EVAPORATOR DRAIN PLUG
DRIER
NUT
HEAT EXCHANGER
ELECTRICAL BOX COVER
OVERLOAD COVER
MALE CONNECTOR FITTING
SLEEVE-COMPRESSOR
ELBOW FITTING
FREEZE CONTROL

ITEM NO.

PARTS LIST

*INCLUDES COMPRESSOR, CSIR BOX ASSY, & OVERLOAD. IF UNDER

WARRANTY REPLACE WITH SAME COMPRESSOR USED IN

ORIGINAL ASSEMBLY.

NOTE: ALL CORRESPONDENCE PERTAINING TO ANY OF THE ABOVE

WATER COOLERS OR ORDERS FOR REPAIR PARTS MUST INCLUDE

MODEL NO. AND SERIAL NO. OF COOLER, NAME AND PART NO. OF

REPLACEMENT PART.

NOTE: FOR USE WITH PHOTO PROCESSING APPLICATIONS,

ADJUST THERMOSTAT TO WARMER SETTINGS.

ELKAY MANUFACTURING COMPANY•2222 CAMDEN COURT•OAK BROOK, IL 60521•630.574.8484•TELEX: RCA 289234

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620

The grounding of electrical equipment such as telephone, computers, etc., to water

lines is a common procedure. This grounding may be in the building, or may occur

away from the building. This grounding can cause electrical feedback into a water

chiller, creating an electrolysis which causes a metallic taste or an increase in the

metal content of the water. This condition is avoidable by using the proper materials

indicated below. Drain fittings which are provided by the installer should be plastic to

electrically isolate the chiller from the building plumbing system.

Temperature Control: Factory set for 50°F water under normal conditions. To

adjust water temperature, turn screw on Item No. 8 clockwise for colder, counter
clockwise for warmer.

Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with

a brush, air hose, or vacuum cleaner. Excess dirt or poor ventilation can cause no

cold water and compressor cycling on the overload protector.

Lubrication: Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free

plug which utilizes an o-ring seal. To remove plug from cooler, relieve water

pressure, pull the collar towards the fitting and pull the fitting off the tube. To install

plug, push fitting straight onto tubing until it reaches a positive stop, approximately

3/4”.

IMPORTANT! INSTALLER PLEASE NOTE:

TROUBLE SHOOTING & MAINTENANCE

START-UP

1. Open supply line valve.

2. Purge all air from all water lines by operating bubbler valve of fountain to which

cooler is connected. A steady stream flow assures that all air is removed.

3. Rotate fan blade to assure proper clearance and free action.

4. Connect to proper electrical power.

TUBE IS SECURED

IN POSITION

SIMPLY PUSH IN

TUBE TO ATTACH

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

19, 28

21

11

9

1

5

6

4

7, 20, 23

8

22

2

3

13, 14, 15, 16, 26

10

24

12

27, 29

18, 25

30

Advertising