Hrc2-1c – Elkay HRC2-1C User Manual

Page 2

Advertising
background image

97385C (REV B - 3/00)

HRC2-1C

ITEM

NO.

PART

NO.

1

2

3

4

5

6

7

8

9*

10

11

12

13

14

15

16

17

18

19

20

21

22

23

30040C

30039C

31513C

31341C

30824C

42677000

111543043890

66266C

35786C

31038C

31797C

19037000

101516143550

100806740570

66200C

66540C

50930C

23105C

27304C

23107C

23108C

23109C

66529C

DESCRIPTION

Cover - Electrical Box

Box - Electrical

Control - Cold

Motor - Fan

Fan - Blade

Fan - Bracket

Nut - Hex #6-32

Condenser

Compressor Service Pak

Overload/Relay

Cover - Relay

Clip - Compressor Mounting

Stud

Grommet

Drier

Evaporator - Assy

Bumper

Cabinet

Baseplate

Panel - Rear (Not Shown)

Panel - Front

Panel - Condenser Mounting

Heat Exchanger

21

15

23

18

3

22

10, 11

4, 5,

6, 7

9

19

17

12, 13, 14

*INCLUDES RELAY & OVERLOAD. IF UNDER

WARRANTY, REPLACE WITH SAME COMPRESSOR

USED IN ORIGINAL ASSEMBLY.

NOTE: All correspondence pertaining to any of the

above water cooler or orders for repair MUST include

model number and serial number of cooler, name and

part number of replacement part.

INSTALLATION

1. It is important to insure proper ventilation. For remote installation a minimum clearance of 6 inches

(152 mm) to the front must be maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear

above the unit. Wall grille EG-1 or EG-2 to be used when unit is inserted into an enclosure. Install unit

as close as possible to wall grille. A 6 inch (152 mm) clearance beyond the front of the wall grille is

required for adequate air circulation.

2. When unit is installed in a kitchen cabinet, two air openings with a minimum of 40 square inches each

(minimum of 75% open area) must be provided in the cabinet. One opening should be in the overhang

of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with

a minimum of 3 inch clearance between the unit and the walls of the cabinet. In addition a minimum 2

inch clearance must be provided between the toe space air opening and front of remote unit.

3. Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply connections as required.

4. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being

connected to chiller. If flushing does not remove all particles, a water strainer should be installed in

supply line.

5. Connect cooler to building supply line with a shut-off valve and install a union connection between the

valve and chiller.

6. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on chiller

serial plate. Never wire compressor directly to the power supply.

START-UP

1. Open supply line valve.

2. Purge air from all water lines by operating bubbler valve of fountain to which chiller is connected.

Steady stream assures all air removed.

3. Rotate fan to insure proper clearance and free fan action.

4. Connect to electrical power.

TROUBLE SHOOTING & MAINTENANCE

Temperature Control: Factory set at 50°F (+/- 5°) under normal conditions. For colder water, adjust

screw on item no. 3 CW.

Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or

vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the

compressor overload prctector.

Lubrication: Motors are lifetime lubricated.

ACTUATION OF QUICK CONNECT WATER FITTINGS:

Chiller is provided with a lead-free plug which utilizes an o-ring water seal. To remove plug from chiller,

relieve water pressure, pull the collar towards the fitting and pull the fitting off the tube. To install plug,

push fitting straight onto tubing until it reaches a positive stop, approximately 3/4 in. (19mm).

1, 2

8

16

Advertising