HOW TO OPERATE YOUR HAND VACUUM

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE REASON

POSSIBLE SOLUTION

HAND VACUUM WILL
NOT OPERATE

1. Power cord not firmly

plugged into outlet.

2. No power in wall outlet.
3. Needs

servicing.

1. Plug unit in firmly.
2. Check

fuse

or

breaker.

Replace fuse/reset

breaker.

Call 514-842-8691

HAND VACUUM WILL
NOT PICK-UP OR
SUCTION POWER IS
WEAK

1. Dust cup filter is full.
2. Unit

clogged.

3. Dust cup filter needs

cleaning.

1. Empty dust cup filter –
(see page 4).
2. Turn unit off and unplug

from wall outlet. Remove
dust cup filter and check
for object(s) in air duct
and remove.

3. Clean or replace dust cup

filter. (see page 4).

DUST ESCAPING
FROM HAND
VACUUM

1. Dust cup filter is full.
2. Dust cup filter is not

installed correctly.

3. Puncture/hole

in

dust

cup

filter.

1. Empty dust cup filter.
2. Review dust cup filter

instructions. (see page 4)

3. Replace dust cup filter.

(see page 4)

HAND VACUUM HOSE
OR BRUSHES WILL
NOT PICK-UP

1. Hose

clogged.

2. Dust cup filter is full.

1. Remove

hose

and/or

bushes. Remove
obstruction from hose.

2. Empty and clean dust cup

filter.

1. Hold the hand vacuum firmly with your hand on the Handle (4).

2. Push the On/Off Power Switch (2) to “On” position.

3. Start vacuuming.

CAUTION:

The Hand Vacuum is a very powerful unit. Make sure

that you hold it firmly, otherwise it can slip out of your
hand and cause injury.

CHANGING & CLEANING THE DUST CUP FILTER

Warning: Always unplug from electrical outlet before opening the Dust Cup

(container) (10).

1. To open the Dust Cup (container) (10), push button (1) and pull out the Dust

Cup (container ) (10), (fig. 1).

2. Pull out the Dust Cup Filter (8), (fig. 2).

3. Empty the dust from the Dust Cup Filter (8).

4. Rinse the Dust Cup Filter (8) in cold water, and then wait until it dries up

before replacing it into the Dust Cup (container) (10).

5. Place the Dust Cup Filter (8) carefully into the Dust Cup (container) (10).

6. Attach the Dust Cup (container) (10) to the Hand Vacuum.

Fig. 1

Fig. 2

CAUTION:

The suction hole (3) must be open, free of any obstructions

at all times. Otherwise, the motor will overheat and could
get damaged.

4