Channel voice messages, Control change – Edirol V-4 User Manual

Page 91

Advertising
background image

91

MIDI implementation

2. MIDI messages transmitted from MIDI

OUT

*

If MIDI Thru is ON, MIDI messages received at MIDI IN are re-transmitted without
change from MIDI OUT.

*

If MIDI Thru is ON, messages from the V-4 itself will not be transmitted.

Channel voice messages

Control Change

*

The messages assigned in MIDI Setup will be transmitted when you operate the panel.
The control changes that can be used are CC#1--5, 7--31, and 64--95. For the factory
settings, refer to “Settings Transmitted/Received Using MIDI” (p. 95).

Bank Select (controller numbers 0, 32)

Status

2nd byte

3rd byte

---------------------------------------------------------------------
BnH

00H

mmH

BnH

20H

llH

mm, ll= bank number:
*

When you select channel A or channel B inputs, make memory settings, or specify how
sub-channels are mixed in Presentation mode, these messages will be transmitted in
conjunction with Program Changes.

*

The following controls correspond to each Bank Select message.

Bank Select

Program No.

Control

MSB/LSB
-------------------------------------------------------------------------------
50H/00H

00H - 07H

MEMORY 1-8

-------------------------------------------------------------------------------
00H/00H

00H - 03H

A ch, INPUT 1-4

-------------------------------------------------------------------------------
01H/00H

00H - 03H

B ch, INPUT 1-4

-------------------------------------------------------------------------------

Modulation (controller number 1)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

01H

vvH

Breath-type (controller number 2)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

02H

vvH

Foot-type (controller number 4)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

04H

vvH

Portamento Time (controller number 5)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

05H

vvH

Volume (controller number 7)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

07H

vvH

Balance (controller number 8)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

08H

vvH

Panpot (controller number 10)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

0AH

vvH

Expression (controller number 11)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

0BH

vvH

Effect Control 1 (controller number 12)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

0CH

vvH

Effect Control 2 (controller number 13)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

0DH

vvH

General Purpose Controllers 1--4 (controller numbers 16-19)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

10H - 13H

vvH

Hold 1 (controller number 64)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

40H

xxH

Portamento (controller number 65)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

41H

xxH

Sostenuto (controller number 66)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

42H

xxH

Soft (controller number 67)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

43H

xxH

Legato (controller number 68)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

44H

xxH

Hold 2 (controller number 69)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

45H

xxH

Sound Controllers 1--10 (controller numbers 70--79)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

46 - 4FH

vvH

General Purpose Controllers 5--8 (controller numbers 80--83)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

50 - 53FH

vvH

Portamento Control (controller number 84)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

54H

vvH

Effect Depth 2--5 (controller number 92--95)

Status

2nd byte

3rd byte

--------------------------------------------------------------------
BnH

5C - 5FH

vvH