Model

Ei405 RF Optical

Installation & Placement

Place the mounting plate on the ceiling/wall and mark the screw holes. Drill
with a suitable drill bit, insert the screw plugs and screw the plate into position.
Simply connect the battery on the alarm and slide into position on the
mounting plate.

The RF alarms should be house coded to prevent possible interference from
neighbouring installations

– see instructions for more details.


Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector

House Code Procedure

1.

Connect the battery

2.

Hold the house code switch
(with a small screwdriver)
until the blue light turns on
and then release

3.

Similarly, place other alarms
into house code mode

4.

Check that the number of
blue flashes (on each alarm)
corresponds to the number of
alarms in your system

5.

Remove all alarms from
house code

6.

Button test each alarm to
check your system

Technical Specification

Sensor

Optical, uses light scatter from
smoke

Sensitivity:

Complies with BS 5446 Part 1:
2000

Automatic Self-Test:

Smoke Chamber is tested every 40

Sec. and unit beeps (without LED

flash) if it is degraded.

Supply Voltage:

9V alkaline battery

RF Range

1

:

150 meters (min) free space

RF Visual Indicator:

Blue light flashes continuously for
1.5 to 3.5 seconds while
transmitting RF signal

RF Frequency:

868.499MHZ (1% duty cycle)

RF Power:

+5dBM

Dimensions:

152mm diameter x 50mm depth

Weight:

286g




Power-On Indicator:

Red light flashes every 40 seconds

Alarm:

Electronic Piezoelectric horn

Alarm Sound Output:

85dB (minimum) at 3m

Alarm Status:

Red LED flashes every second on

unit sensing fire

Temperature Range:

0

0

to 40

0

C

Humidity Range:

15% to 95% Relative Humidity

Interconnect:

Up to 12 RadioLINK products

Plastic material:

UL94VO flame retardant

Warranty:

5 year (limited) warranty

Approvals:

Kitemarked to BS EN 14604: 2005,
CE Approved

Specifications are subject to change