Ei Electronics Ei 261EN User Manual

Page 27

Advertising
background image

Electromagnetic

: Complies with BS EN 50270

Compatibility

Test/Hush Button

: Checks electronics and horn.

When the unit is alarming, after sensing CO, pressing the test/hush button will immediately stop the
horn (the red light will continue to flash). If CO is still present the red light and the horn will turn on
again after about 4 minutes. The unit can only be silenced once during a CO incident. At 300 ppm
CO the unit cannot be silenced. (With interconnected units, the hush only works on the alarm
sensing CO).

Fast CO Test Mode

: Pressing the test button also causes the unit to check for CO, 4 seconds

later to facilitate testing in CO gas. It gives 3 beeps and the red light
flashes to indicate the CO level, if CO is sensed and then resets.

Initialisation Time

: 70 seconds. On power up red and amber lights flash momentarily to show
they are operational.

Operating

: -10°C to 40°C

Temperature

Humidity Range

: 15% to 95% R.H. (non-condensing)

Audible Alarm

: 85dB(A) at 3m minimum

Self Diagnostics

: Horn beep and amber fault light flashes every 40 seconds if a sensor fault is found.

Tamperproof

: Screwdriver needed to release from mounting plate. Additionally a tamper-

proofing screw can be fitted to mounting plate.

25

B15404-R0-261EN-UC-ENG 31/5/07 2:01 PM Page 27