Pressure Systems 9016 User Manual

Page 6

Advertising
background image

Pressure Systems, Inc.

9016 Upgrade Instructions

www.PressureSystems.com

5

Viton

®

gasket

Figure 4

9016 Out of Housing

Wiring harness

Figure 5

PC-206 Board

Phillips head screws

Electronic Circuit Board Replacement

Your 9016 contains two (2) electronic circuit boards that must be removed and replaced for this
upgrade.

PC-206 Amplifier/Multiplexer Board

The following procedures should be used for removal of the PC-206 Amplifier/Multiplexer Board.
Use the tools and follow the general precautions previously described.

(1)

Carefully remove the wiring harness from connector P1 of the PC-206 board. (See
Figure 5.)

(2)

Remove the two (2) Phillips-head screws securing the PC-206 board to the DH200
transducers. Carefully disconnect the PC-206 board from the DH200s by slowly working
the board off; starting at one end and moving down the length of the board. It is important
to not break the gold pins when removing the board. Inspect the PC-206 boards for broken
pins and remove from DH200 transducers, if neccessary.

Advertising