Noises during operation – Electrolux ARCTIS 1050GS8 User Manual

Page 20

Advertising
background image

20

Symptom

Possible Cause

Remedy

Heavy build up of frost,
possibly also on the door
seal.

Door seal is not air tight
(possibly after reversing
the door).

Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.

The compressor starts after
a period of time.

This is normal, no error has
occurred.

The compressor does not
start immediately after
changing the temperature
setting.

Important: regularly check on the warning light to ensure that the
storage temperature is being maintained.

Noises during Operation

The following noises are characteristic of refrigeration appliances:
Clicks

Whenever the compressor switches on or off, a click can be heard.

Humming

As soon as the compressor is in operation, you can hear it humming.

Bubbling/Splashing

When refrigerant flows into thin tubes, you can hear bubbling or
splashing noises. Even after the compressor has been switched off,
this noise can be heard for a short time.