Instructions for the Installer

Engineers technical data

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

NOMINAL THERMAL

POWER (kW)

2.9

0.65

1.9

0.45

1.0

0.33

NOMINAL FLOW

RATE (m

3

/h)

0.276

0.062

0.181

0.043

0.095

0.028

NOZZLE REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

(1/100 mm)

NOMINAL THERMAL

POWER (kW)

2.7

0.65

1.9

0.45

1.0

0.33

NOMINAL FLOW

RATE (g/h)

195

46.8

137

32.4

72

23.8

NOZZLE REFERENCE

86

40

71

32

50

28

(1/100 mm)

NATURAL GAS

20 mbar

VALUE =

37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

TYPE OF GAS

LPG GAS

28-30/37 mbar

VALUE =

49.92 MJ/Kg

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Rapid

40

Aeration adjustment none

Supply Connections

Gas: RC 1/2 inch (1/2 inch male) Rear right

hand corner

Electric: 230-240V 50Hz supply, 3 core flexible

cable with non rewireable plug fitted with a 3 amp

cartridge fuse.

Ignition HT Spark

Spark Generator: Ispra Control's BF 50066 -

230-240V 0.6 YA T120

Spark Gap : Fixed

Overall dimensions

Width:

740 mm.

Depth:

520 mm.

Cut out dimensions

Width:

560 mm.

Depth:

480 mm.

Heat Input

Semi-rapid Burner 1.9 kW (6483 BTU/HR)
Rapid Burner

2.9 kW Natural Gas

(9895 BTU/HR)

2.7 kW L.P.G.

(9212 BTU/HR)

Auxiliary Burner

1.0 kW (3412 BTU/HR)

Appliance class

3

Appliance category

II2H3+

Gas supply

Natural gas G20 / 20mbar

Advertising