Technical specifications – Eicon Networks Diva Server Adapters User Manual

Page 19

Advertising
background image

Technical Specifications

19

Technical Specifications

Environmental requirements

• Operating temperature: 15 degrees C to 70 degrees C

• Operating humidity: 10 to 85% (non-condensing)

• Barometric operating pressure: 86 to 106 kPascals

• Maximum tolerance in power supply variation: -5% to +5%

Diva Server T1/PRI
Diva Server Voice T1/PRI

Bus type

PCI (3,3/5 V)

CPU

32 Bit RISC CPU, 180 MHz

Memory

8 MB SDRAM

Interrupt request levels

Allocated by PCI BIOS.

I/O base addresses (hex)

Allocated by PCI BIOS.

Shared memory range

8 MB

DSPs

Diva Server T1/PRI:
either 2, 4, 8, or 24 ADSPs 2185L according to model
Diva Server Voice T1/PRI:
either 4, 8, or 24 ADSPs 2185L according to model

Dimensions

T1/PRI: half size PCI
T1/PRI-4M, T1/PRI-8M, T1/PRI-24M: full size PCI

Data transfer rate

23 x 64 kbps B-channel
1 x 64 kbps D-channel (PRI)
or
24 x 56 kbps (channelized T1)

Plug&Play

yes

Power safe mode

yes

External interface

Female RJ-45 (PRI)

Performance

Primary rate interface (up to 24 channels @ 64 kbps each)
channelized T1 interface (up to 24 channels @ 56 kbps each)

Power requirements

T1/PRI-24M:
1,7 A @ +5 V typ.